CONTROLLER
Timer Operation
In normal operation, the Time of Day display will alternate being viewed with the Days
Remaining display. This display will be in gallons (options are liters or cubic meters). As treated
water is used, the Days Remaining display will count down from a maximum value to zero or
(- - -). Once this occurs, a regeneration cycle will be initiated at the Set Regeneration Time.
Water ow through the valve is indicated by the Flow Indicator that will ash in direct
relationship to ow rate.
Time Clock Delayed Control (Factory Default Setting)
A Time Clock Delayed Control regenerates the system on a timed interval. The control will initi-
ate a regeneration cycle at the programmed regeneration time when the number of days since
the last regeneration equals the regeneration day override value.