OPERATIONS MANUAL
RESIDENTIAL FILTRATION SYSTEMS
WITH FLECK 2510 AIO CONTROL VALVE
PROFESSIONAL II SERIES
MODEL NO. ______________________
SERIAL NO. ______________________
The Blake Group
BWS
TM

Questions and Answers

  • T
    thomasmicheleAug 5, 2025
    What to do if my BWS Control Unit shows a Regen Failure?
    • M
      Michael YoungAug 5, 2025
      To resolve a Regen Failure in your BWS Control Unit, start by performing a manual regeneration to clear the error. If your system is metered, ensure it's measuring flow by observing the flow indicator during water usage. If there's no flow measurement, check the meter cable connection and meter functionality. Access Master Programming Mode to confirm correct unit configuration, including system capacity, day override settings, and meter identification. For Day-of-Week systems, verify that at least one day is set to ON. Adjust any incorrect settings accordingly. This issue arises when the system hasn't regenerated for over 99 days, or 7 days if set to Day-of-Week mode.
  • H
    Henry HuntAug 11, 2025
    How to fix a Cam Sensor Error on a BWS PROFESSIONAL II Control Unit?
    • A
      Alan CoxAug 12, 2025
      If your BWS Control Unit displays a Cam Sensor Error, the valve drive might have taken longer than 6 minutes to advance to the next regeneration position. Begin by unplugging the unit and inspecting the powerhead. Ensure all cam switches are properly connected to the circuit board and functioning. Verify the motor and drive train components are in good condition and correctly assembled. Check the valve to ensure the piston moves freely. Replace or reassemble components as needed. Plug the unit back in to observe its behavior; it should cycle to the next valve position and stop. If the error persists, unplug the unit and contact technical support.
  • A
    Amanda BrownAug 17, 2025
    What to do if my BWS PROFESSIONAL II Control Unit displays a Cycle Step Error?
    • J
      Jason KirbyAug 17, 2025
      If your BWS Control Unit is showing a Cycle Step Error, it means the control experienced an unexpected cycle input. Unplug the unit and check the powerhead, ensuring all cam switches are properly connected to the circuit board and functioning correctly. Enter Master Programming mode to verify that the valve type and system type are correctly configured for your unit. Manually step the unit through a regeneration cycle to confirm it functions as expected. If the error continues, unplug the unit and contact technical support.
  • C
    Colleen HouseAug 23, 2025
    How to resolve a Memory Error on a BWS PROFESSIONAL II?
    • M
      Michael OrtizAug 23, 2025
      If your BWS Control Unit displays a Memory Error, it indicates a control board memory failure. Perform a Master Reset and reconfigure the system through Master Programming Mode. After reconfiguration, manually step the valve through a regeneration cycle. If the error reappears, unplug the unit and contact technical support.
  • E
    Eric HillAug 29, 2025
    Why does my BWS Control Unit show an Upper Drive Synch error?
    • S
      stephanie91Aug 30, 2025
      The valve will automatically recover from an Upper Drive Synch error on your BWS Control Unit. This issue is caused by a power failure during an install programming change.

Summary

System Introduction and Installation Requirements

Introduction to Aeration Systems

Explains the function of the aeration filter system and its benefits.

Installation Requirements

Details essential water pressure, electrical supply, and plumbing conditions.

Installation Procedures

Tank and Valve Installation

Covers unit placement, drain line setup, check valve, and deflector installation.

Plumbing and System Initialization

Includes bypass operation, flushing, media notes, and power connection.

Controller Functionality

Controller Settings and Operation

Explains default regeneration schedules, frequency adjustments, and display modes.

Control Operations

Covers regeneration, programming, and power failure handling.

Timer and Regeneration Controls

Details setting the time, queuing, and manually advancing regeneration steps.

Regeneration Cycle Details

Regeneration Cycle Phases

Explains the Backwash, Air Recharge, Rapid Rinse, and Brine Fill steps.

Bypass and Hydration

Covers automatic bypass during regeneration and media hydration needs.

SXT System Programming

Entering and Exiting Programming Mode

Steps to enter, navigate, and exit the master programming mode.

Programming Parameters

Definitions for programming abbreviations and their options.

Media Installation and Commissioning

Preparing for Media Loading

Disconnecting valve, preparing riser tube, and loading gravel.

Media Loading and Hydration

Loading media, securing valve, and crucial media hydration steps.

System Disinfection

Procedures for disinfecting the system after installation.

Troubleshooting Error Codes

Error Code 0: Cam Sensor Error

Cause and recovery for slow valve drive.

Error Code 1: Cycle Step Error

Cause and recovery for unexpected cycle input.

Error Code 2: Regen Failure

Cause and recovery for system not regenerating.

Error Code 3: Memory Error

Cause and recovery for control board memory failure.

Error Code UD: Upper Drive Synch

Cause and recovery for power failure programming changes.