Regeneration Cycle (55 minutes):
Automatic Bypass during Regeneration
The lter is factory set to regenerate at 12:00 a.m., normally a period of little or no water use.
The regeneration cycle lasts approximately 55 minutes, after which ltered water service is
restored.
While the regeneration cycle is in progress raw water will automatically bypasses the lter if
required. If possible, avoid using water during this time to prevent untreated water entering
your household plumbing system.
The programmed regeneration time may be changed to accommodate households with varying
schedules, however once set to meet water quality requirements the cycle duration times
should not be changed.
1. Backwash (14 minutes):
During this cycle, the water carrying the iron runs to the drain. Untreated water is available
during regeneration.
2. Air Recharge (40 minutes):
During this cycle, the unit empties water to drain and is recharged with air. The sound of air
being recharged will be heard. Air bubbles should go down to the drain before proceeding to
the next step. Adjust cycle time if necessary.
3. Rapid Rinse (1 minute):
During this cycle, water enters the tank, compressing the air into a pocket at the top of the
tank.
4. Brine Fill (OFF)
7