EasyManua.ls Logo

BYGD SW2000 - Page 8

BYGD SW2000
46 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
8
Operation Guide
After long press the switch for 1 second, the socket outputs 220VAC, connect the
load to be run to AC output socket or USB port.
If the load power exceeds the rated power, the overload protection will start and
the product will shut down automatically. Please reduce the load and connect a
load with lass than the rated power after the product restarts.
When the battery voltage drops to 10V, the under-voltage protection function will
start and the product will automatically shut down. This can prevent the battery
from being damaged and ensure that the battery needs enough power when the
car starts.
If the working temperature of the product exceeds the safe operating
temperature due to poor ventilation or high external temperature, the
overtemperature protection function will be activated and the product will be
automatically shut down, and it will automatically resume working when it
returns to normal temperature.
If a defective battery charging system causes the battery voltage to rise to a
dangerous level greater than 18.5V, the overvoltage protection function will start
and the product will be automatically shut down.
CAUTION
Although this product is equipped with overvoltage protection, it may still damage the
product if the input voltage exceeds 17V.