ACTIVE 5
ENGINEERING
MANUAL
C & K Systems Ltd C031-066 Issue 3
Question and Answer IconNeed help?

Do you have a question about the C & K Systems ACTIVE 5 and is the answer not in the manual?

C & K Systems ACTIVE 5 Specifications

General IconGeneral
BrandC & K Systems
ModelACTIVE 5
CategoryOther
LanguageEnglish

Summary

Active 5 Installation Overview

Introduction and System Planning

Introduces the Active 5 panel, its features, and planning considerations for installation.

Special Features

Highlights features like non-volatile memory and zone isolation for false alarm prevention.

User/Customer Code Defaults

Details how to restore the panel to its factory default settings using a jumper link.

Panel Mounting and Wiring

Mounting Instructions

Step-by-step guide for physically mounting the alarm control panel securely.

Control Panel Wiring

Covers mains connection, battery connection, and detector circuit wiring.

Detector and Sounder Connections

PIR Latch Line and Detector Reset

Explains L+ connection for PIRs and using 'ID' output for detector reset.

Internal and External Sounders

Details the internal speaker and connections for external sounders and strobes.

System Configuration and Setting Options

Auxiliary Power and Keypad Wiring

Describes auxiliary power for detectors and wiring requirements for remote keypads.

Setting Methods Explained

Outlines three methods for setting the alarm system: Timed exit, Exit terminate, Door sense.

Alarm Outputs and Line Fault Input

Line Fault Input

Information on using line fault terminals for the Active 5X comms version.

Alarm Output Details

Describes various alarm outputs including relays, strobe, internal sounder, and trigger outputs.

Initial Power Up and Engineering Mode

Initial Power Up Procedure

Steps for powering up the panel, silencing sounders, and entering programming mode.

Exiting Engineering Mode

Methods to exit engineering mode, including automatic exit and manual exit.

Engineer Code and Bell Delay

Details the default engineer code and how to configure the full set bell delay.

Timer Settings and Zone Programming

Exit and Entry Timer Configuration

How to program Exit Time, Entry Time, Bell Duration, and Night Set Exit Time.

Zone Programming Options

Guide to programming zone types and attributes using the 4-X options.

Zone Programming Reference

Circuit Programming Matrix

A reference guide to programming zone types and applicable options using LEDs.

Zone Attributes Explained

Meanings of zone types like Alarm, Entry Zones, 24 Hour, Fire, and PA zones.

Zone Type Definitions

Advanced Zone Types

Definitions for 24 Hour, Fire, Personal Attack, Home/Night Set isolate, Walk Through zones.

Zone Options: Chime and Isolation

Explains Chime zones, Isolate Permit, and Bells & Strobe options.

Warning Tones and Event Logging

Warning Tone Configuration

Defines the Warning Tone option for a 24 hour zone.

Example Zone Programming

A practical example demonstrating how to program Zone 1.

Engineer Event Log Review

Instructions on how to access and review SET/UNSET events, alarms, and isolated zones.

System Options Configuration

Night Set and Home Set Options

Configuration options for Night Set and Home Set modes.

Engineer and Line Fault Options

Settings related to engineer reset, PA alarms, and line fault detection.

European Options and Bellbox Connections

European Options

Options specific to European standards, including LED flashing and auto-isolation.

Bellbox Connection Guide

Table detailing connections for various bellbox models to the Active 5 Panel.