Gas Setup for Natural Gas (Conversion kit required)
1. With burner in place in CabanaCoast® re pit ta-
ble or other installaon locaon and proper
sized orice inserted in burner neck (see chart
on p.4 for natural gas orice sizing), adjust air
shuer to a closed posion (as shown at right,
no light visible through the shuer) by loosening
the small screw on the air shuer and rotang it
to a closed posion and re-ghtening screw.
2. Locate the included metal ex-line hose and
thread one end onto orice and ghten securely
with two wrenches.
3. At this point if you are connected to natural gas
using a valve assembly such as The CabanaCoast® valve
kit, proceed to step 3a.
3a. Aach the free end of ex hose to the top
outgoing) are ng of control valve and ght-
enfully with two wrenches. Plumb incoming nat-
ural gas to the incoming side of the valve using a
3/8” are nut. It is strongly recommended that a
manual shuto valve is placed in the natural gas
line before it reaches the re pit’s control valve.
CabanaCoast® fire pit Control panel kit
CHECK ENTIRE SYSTEM FOR LEAKS BEFORE OPERATING