EasyManua.ls Logo

Cadel Diana - User Manual

Cadel Diana
320 pages
Go to English
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
©2013 CADEL srl | All rights reserved – tutti i diritti riservati
it
STUFA A PELLET
manuale di installazione, uso e manutenzione
en
PELLET STOVE
installation, use and maintenance
fr
POÊLE À GRANULÉS
manuel dinstallation, utilisation et entretien
es
ESTUFA DE PELLETS
manual de instalación, uso y manutención
nl
PELLETKACHEL
handleiding voor installatie, gebruik en onderhoud
pt
ESTUFAS A PELLET
manual para instalação, uso e manutenção
el
ΣΟΜΠΕΣ PELLET
εγκατασταση, χρηση και συντηρηση
nice - miriam - cristal - leonora - pretty - diana - kriss - mary

Table of Contents

Other manuals for Cadel Diana

Questions and Answers

  • A
    Alison BruceAug 18, 2025
    Why Cadel Stove is not igniting and shows “AlAr no FirE” or “no Acc” alarm?
    • D
      Donald BakerAug 18, 2025
      The Cadel Stove might not be igniting due to several reasons. The hopper might be empty, so you should fill it. The burn pot may not have been cleaned, so clean the burn pot. The probe may not have reached ignition, so empty the burn pot and light again. The external temperature could be too low, so start the stove again. The pellets might be damp, ensure pellets are stored in a dry place.
  • G
    Gary MooreAug 20, 2025
    What to do if my Cadel Diana Stove control panel not turns on?
    • C
      Cody MillerAug 20, 2025
      If the control panel of your Cadel Stove isn't turning on, first ensure the stove is properly plugged into the mains. If it is, the circuit board protection fuse might be burnt, or there may be a faulty control panel, flat cable, or electronic circuit board. Replacing the board protection fuse may help. For other potential causes like a faulty control panel, flat cable, or electronic circuit board, it is recommended to consult an expert.
  • S
    stephaniehughesAug 23, 2025
    What to do if my Cadel Diana Stove goes off and displays “AlAr dEp”?
    • K
      Kimberly PetersonAug 23, 2025
      If your Cadel Stove goes off and shows the “AlAr dEp” alarm, it could be due to several reasons. Ensure the door is properly closed and check the state of the gaskets, replacing them if necessary. The outlet might be clogged, so have an expert check the exhaust pipe. The hose holder attachment could be clogged; detach the silicone pipe from the hose holder and use a pointed metal tool to clean the hose holder hole, replacing the silicone pipe if necessary. Also, bad weather conditions or temporary power failure can cause this issue, so check and restart the stove. If the boiler is overheating, let the stove cool; the thermostat will restart automatically.
  • K
    Katherine LeonAug 26, 2025
    Why my Cadel Stove fire extinguishes and stops?
    • J
      jason04Aug 26, 2025
      Your Cadel Stove might be extinguishing and stopping due to a few reasons: * The hopper could be empty, so ensure you fill it. * The auger might be clogged by a foreign object; unplug the stove, remove any hand protection in the hopper, empty it, clean the auger, and restart. * You might be using low-quality pellets, so try using other types of pellets.
  • D
    Dennis BrownAug 28, 2025
    What to do if pellets not reaching combustion chamber in Cadel Stove?
    • N
      Nicole BlackAug 28, 2025
      If pellets are not reaching the combustion chamber in your Cadel Stove, the hopper might be empty, so fill it. Alternatively, the auger could be clogged by a foreign object. In this case, unplug the stove, remove any hand protection in the hopper, empty it, clean the auger, and restart.
  • J
    Joshua FowlerAug 30, 2025
    What does it mean when Cadel Stove goes off and displays “AlAr no rEtE”?
    • T
      Troy BarnesAug 30, 2025
      If your Cadel Stove goes off and displays the “AlAr no rEtE” alarm, it could be due to the plug being accidentally disconnected, so check that it is plugged into the mains. It may also be due to a temporary power failure, so check and restart the stove.
  • D
    David Morgan MDSep 2, 2025
    Why Cadel Stove has a weak orange flame and blackens the glass?
    • C
      Carolyn Graves PhDSep 2, 2025
      A weak orange flame in your Cadel Stove, along with improperly burning pellets and blackened glass, can be caused by not enough combustion air. Check for obstructions to air entry at the back of the stove. Also check ash clogged holes in the burn pot grid and/or seat. The exhaust could also be obstructed, so it is important to have the outlet chimney checked for clogs and cleaned immediately. The stove itself might be clogged, requiring a cleaning.
  • C
    Calvin HermanSep 4, 2025
    Why Cadel Stove goes off and displays "AlAr HottEmp”?
    • L
      lstewartSep 4, 2025
      If your Cadel Stove goes off and displays "AlAr HottEmp”, it can be caused by a faulty fumes probe.
  • P
    phillip72Sep 7, 2025
    Why does the heat exchanger fan keeps turning on my Cadel Diana Stove?
    • C
      charlesfloresSep 7, 2025
      If the heat exchanger fan in your Cadel Stove keeps turning even after the stove has cooled, it could be due to a faulty fumes temperature probe.
  • J
    John SullivanSep 9, 2025
    What does it mean when Cadel Stove goes off and displays “AlAr Sond”?
    • D
      Danielle BrownSep 9, 2025
      If your Cadel Stove goes off and displays “AlAr Sond”, it may be due to the fumes temperature probe.

Summary

Cautions

Chimney Flue

Technical Features

External Air Inlet

Chimney Flue Connection

Examples of Correct Installation

Installation

General Installation

Electric Connection

Connection to the External Thermostat

Use

10.1 Attention

Critical safety warnings and precautions for using the appliance.

Control Panel

User Menu

Start Up

Stove Adjustment

Failed Ignition

Power Failure

Temperature Setting

Switching Off

Clock Setting

Daily Programming

Week-End Programming

Weekly Programming

Fire Extinguishing in Case of Fire

Pellet Supply

Safety System

11.1 Introduction

Overview of the safety devices designed to prevent hazards.

11.2 Black Out Alarm

Procedure for resolving the 'Black Out' alarm condition.

Hot Fume Alarm

Fan Failure Alarm

Failed Ignition Alarm

No Pellet Alarm

Thermal Safety Alarm

Failure Depress Alarm

Maintenance

Hopper and Auger Cleaning

Fume Chamber Cleaning

Fume Conduit Cleaning

Fume Fan Cleaning

Fume Passages Cleaning

Fume Pipes Annual Cleaning

Gasket Replacement

Glass Cleaning

In Case of Anomaly

Problem Solving

Technical Datas

Spare Parts

Declaration of Conformity

Cadel Diana Specifications

General IconGeneral
BrandCadel
ModelDiana
CategoryStove
LanguageEnglish