cadetheat.com Tel: 360-693-2505 PO Box 1675 Vancouver, WA 98668-1675
Benets You Can Depend On
SAVE THESE INSTRUCTIONS
Com-Pak Heater
Owners Guide
1”
2.54
9”
22.86
Side Grill Front Wall Can Side
Wall Can Bottom
12”
30.48
10”
25.4
11
1
/
8
28.26
3¼”
8.26
1¼”
3.18
1¾”
4.45
1¼”
3.18
3”
7.62
4”
10.16
7
7
/
8
20.00
10”
25.4
12”
30.48
11
1
/
8
28.26
3”
7.62
14½”
36.83
16¼”
41.27
1”
2.54
4”
10.16
7
/
8
2.22
Side Grill Front
Wall Can Bottom
Wall Can Side
DUAL SAFETY FEATURES
Primary: “power reset” thermal switch
Secondary: over temperature thermal fuse
Heating element style quickly warms your room,
and quickly cools when heater is not in use
Common sense components designed with you
in mind
1. NO sharp edges
2. Corrosion resistant
3. Easy to install heater, one screw
4. Easy to install wall can
Your Cadet heater has been thoroughly tested
and is guaranteed with a 2 year extended
warranty
(1)
Standard built-in thermostat is single pole and has no “OFF” position.
(2)
240 volt models can be used at 208 volts. Wattage equals 75% of 240v rated
wattage.
Com-Pak Models
Line
Voltage
Model w/o
Thermostat
Model w/
Thermostat
(1)
Watts Amps
120
CS051 CS051T 500 4.2
CS101 CS101T 1000 8.3
CS151 CS151T 1500 12.5
208
CS058 CS058T 500 2.4
CS078 CS078T 750 3.6
CS108 CS108T 1000 4.8
CS118 CS118T 1100 5.3
CS158 CS158T 1500 7.2
CS208 CS208T 2000 9.6
240
(2)
CS052 CS052T 500 2.1
CS072 CS072T 750 3.1
CS102 CS102T 1000 4.2
CS122 CS122T 1250 5.2
CS152 CS152T 1500 6.3
CS202 CS202T 2000 8.3
Com-Pak Twin Models
Line
Voltage
Model w/o
Thermostat
Model w/
Thermostat
(1)
Watts Amps
208
CST308 CST308T 3000 14.4
CST408 CST408T 4000 19.2
240
(2)
CST102 CST102T 1000 4.2
CST152 CST152T 1500 6.3
CST202 CST202T 2000 8.3
CST302 CST302T 3000 12.5
CST402 CST402T 4000 16.7
TOOLS REQUIRED:
• Phillips Screwdriver
• Straight Screwdriver
• Wire Strippers
• Utility Knife
• (4) 1 1/2“ Wood Screws
• Insulated Wire Connectors
• (1) Strain Relief Connector
http://www.cadetheat.com/products/wall-heaters/com-pak
Page 1
Com-Pak
Com-Pak Twin
Com-Pak and
Com-Pak Twin
Models Without
Thermostat
*Wall Thermostat
Required
Com-Pak and
Com-Pak Twin
Models With
Thermostat
*Wall Thermostat Not
Required
Built-in Thermostat
Rating Label

Other manuals for Cadet CS101

Questions and Answers

  • R
    Rhonda ManningAug 7, 2025
    What to do if Cadet Heater will not shut off?
    • H
      hollowayjamieAug 7, 2025
      If your Cadet Heater won't shut off, it could be due to: * **Heat loss:** If heat loss from the room is greater than the heater's capacity, close doors and windows, add insulation, or install a higher wattage heater (if your circuit can handle it). * **Defective thermostat:** Adjust the thermostat to its lowest setting and wait two minutes. If the heater continues to run and the room temperature is above 50°F, replace the thermostat. * **Incorrect wiring:** The thermostat might be wired incorrectly. Refer to the thermostat documentation and correct the wiring.
  • M
    Mary RobinsonAug 11, 2025
    Why Cadet CS101 fan operates, but doesn't discharge warm air?
    • C
      conleytonyaAug 11, 2025
      If your Cadet Heater's fan is running but not producing warm air, consider the following: * **Insufficient element temperature:** Allow a few moments for the element to reach its operating temperature. * **Incorrect supply voltage:** Verify that the supply voltage matches the heater's rating. * **Failed element:** The heating element may need to be replaced. * **(Model CST only) Over temperature controls:** Reset the heater unit. CST models have two heating units with independent over-temperature controls. One of the high-temperature manual power reset controls may trip and cut power to one of the heating units, while the other remains running, resulting in only half output.
  • N
    Natalie BrownAug 21, 2025
    What to do if Cadet CS101 Heater element heats for a moment then stops?
    • M
      Michael ThompsonAug 21, 2025
      If your Cadet Heater element heats briefly and then stops, it could be due to: * **Defective motor or internal connection:** The heater or fan motor may require replacement. * **Fan or motor jammed:** Remove any obstruction and follow the instructions in the “Operation & Maintenance” section for “Resetting the Manual Power Reset Limit Control.” If the heater still doesn't run, it may require repair or replacement.
  • D
    Douglas MaloneAug 27, 2025
    Why does my Cadet Heater breaker trip immediately?
    • N
      nalexanderAug 27, 2025
      Your Cadet Heater's breaker might be tripping immediately due to several reasons: * **Incorrect supply voltage:** Ensure the supply voltage matches the heater's rating. * **Overloaded circuit:** The total amperage of all heaters on the circuit shouldn't exceed 80% of the breaker's rating. Consider using a lower wattage heater or reducing the number of heaters on the circuit. * **Short circuit:** Inspect the supply and heater wiring for any damage to the insulation. Do not reset the breaker until all shorts are repaired. * **Defective circuit breaker:** The circuit breaker may need to be replaced.
  • T
    Taylor BowmanSep 1, 2025
    Why does my Cadet Heater discharge smoke or emit a burnt odor?
    • S
      Stephanie FlemingSep 1, 2025
      If your Cadet Heater discharges smoke or emits a burnt odor, it's likely due to dust, lint, or other matter accumulated inside the heater. Clean the heater following the instructions in the “Operation & Maintenance” section.
  • M
    Mary Dean DDSNov 16, 2025
    Why Cadet Heater does not run?
    • T
      Thomas LeeNov 16, 2025
      Your Cadet Heater might not be running for these reasons: * **Thermostat setting:** Adjust the thermostat to a higher temperature. * **Tripped power reset:** Follow the instructions in the “Operation & Maintenance” section for “Resetting the Manual Power Reset Limit Control.” If the room temperature is below 45°F, see the “Reset Heater at the Circuit Breaker” instructions. * **Tripped secondary fuse:** A severe over-temperature condition has occurred. The heater may need repair or replacement. * **No power:** Turn on the correct circuit breaker in the main panel. * **Wiring issues:** Turn off the power at the circuit breaker and check the supply wire continuity and connection to the heater wires. * **Defective thermostat:** The heater or its components may be checked for conti...

Summary

Benefits You Can Depend On

IMPORTANT INSTRUCTIONS

INSTALLATION INSTRUCTIONS

How do I install for new construction?

Step-by-step guide for installing the heater in new construction settings.

How do I install in an existing wall?

Step-by-step guide for installing the heater in an existing wall.

How do I install for a ceiling mount?

Instructions for mounting the heater for ceiling installation.

How do I insert the heater assembly into the wall can?

Procedures for inserting the heater assembly into the prepared wall can.

OPERATING INSTRUCTIONS

How to operate your heater

Guidance on using the heater controls and setting room temperature.

Resetting the Manual Power Reset Limit Control

Steps to reset the heater's manual power limit control for continued operation.

Warranty

Parts and Service

Information on how to obtain replacement parts and authorized service.

Reduce-Reuse-Recycle

Information on product recycling and environmental considerations.

MAINTAINING YOUR HEATER

Troubleshooting Chart

A guide to diagnose and resolve common heater operational problems.

Cadet CS101 Specifications

General IconGeneral
BrandCadet
ModelCS101
CategoryHeater
LanguageEnglish

Related product manuals