Page 29
WARRANTY CONDITIONS.
The following exclusions apply to the Warranty given by Calorex Heat Pumps Ltd. No claims will be accepted if : -
1. The heat pump is incorrectly sized for the application.
2. The heat pump is installed in any way that is not in accordance with the current procedures as defined by
Calorex Heat Pumps Ltd.
3. The heat pump has been worked upon or is adjusted by anyone other than a person authorised to do so
by Calorex Heat Pumps Ltd.
4. The air flow to and from the machine is outside the specified limits.
5. The water flow through the machine is outside the specified limits.
6. The water pH level and/or chemical balance is outside the following limits:-
Acidity pH: 7.4 ± 0.4
Total Alkalinity, as CaCo
3
ppm 80 -120
Total Hardness, as CaCo
3
ppm 100-300
Total Dissolved Solids: ppm MAX 3000
Maximum Salt Content: wt/wt 6%
Free Chlorine Range: ppm 1.0 - 3.0
Superchlorination: ppm MAX 30 for MAX 24hrs
Bromine: ppm 2-3
Baquacil: ppm 25 - 50
Ozone: ppm 0.8 - 1.0
*Maximum Copper Content: ppm MAX 2
*Aquamatic Ionic Purifier: ppm MAX 2
*Tarn Pure Purifier: ppm MAX 2
*Sherwood Purifier: ppm MAX 2
7. The heat pump has suffered frost damage.
8. The electrical supply is insufficient or in anyway incorrect.