5.8 Fix by front hooking the support brackets for electric cables on the drive
unit profile. The brackets support cables should be positioned along the path
of the electrical cables in order to prevent it from interfering with the
running of the carriages.
5.9 AUTOMATION CLOSING
- Screw the brackets for the magnetic coupling on the cover profile [102] 15 mm from the edge (as shown in figure).
- If you need, insert the cover-leaf gasket [165] on the cover profile [102] to reduce the slit bottom of automation.
- Hang the cover profile [102] to the drive unit profile. The drive unit profile is kept closed by magnets on the end caps.
Note: To avoid that the cover can be opened without the use of a tool, it is necessary to make two 5 mm holes in diameter at
the ends of the cover profile [102], as shown in the figure, and fix the cover with the screws 4,8 x13 in provided (Note: use
the screw located near the magnet).