12.10 ELECTRICAL CONNECTION OF PROXIMITY SENSOR 001MS9502
Connect the terminals of the sensor, by
cable not supplied by us, to the
terminals of the electronic control as
follows:
POWER = terminal 0
POWER = terminal 1
COM = terminal 1
NO = terminal 3A, or 3B
For more information, check the installation manual of the sensor.
12.11 ELECTRICAL CONNECTION OF TRANSPONDER PROXIMITLY READER 001TSTM1
Connect the badge reader to terminals
of the electronic control as follows:
black wire = terminal 0
red wire = terminal 1
white wire = terminal 1
white wire = terminal KO
For more information, refer to the installation manual of the transponder reader.