13.3 ADVANCED PARAMETERS MENU
Using the buttons ↑ and ↓ select ADV, press ENTER to select and adjust the following advanced parameters.
OSSM
OPENING
SAFETY
MOTION
Setting the slowdown distance of the opening sensors (see 6A/6B terminals). Choose between the
following values:
NO = no slowdown
100 / 200 / 300 / 400 / 500 = the door slows down in the last 100/ 200/ 300/ 400/ 500 mm of opening
YES = the door slows down during the whole opening
Setting the stopping distance of the opening sensors (see 6A/6B terminals). Choose between the
following values:
NO = no stop
100 / 200 / 300 / 400 / 500 = the door stops in the last 100/ 200/ 300/ 400/ 500 mm of opening
Selecting type of locking device. Choose between the following values:
LK1 = bistable locking device (SL5LD)
LK2 = safety brake device (SL5SB)
Selecting type of lock operation. Choose between the following values:
AUTO = unlocked with automatic operation while locked with unidirectional operation and door
closed
UNLK = always unlocked with automatic operation and unidirectional
EMERGENCY - Automatic setting for Emergency automation.
LOCK = always locked the door closed
Setting the push on the closed mechanical stop. Choose between the following values:
NO = no push
MIN = light push
MED = medium push
MAX = heavy push
Setting of the opening push. Choose between the following values:
NO = no push
YES = push enabled
Setting the push of keeping the door open. Choose between the following values:
NO = no push
MIN = light push
MED = medium push
MAX = heavy push
Push opening activation. Choose between the following values:
NO = disable
YES = enable
Open door time setting, after the 1-KO command. Choose between the minimum and maximum:
NO = see MENU > TAC
minimum value = 1 s
maximum value = 30 s
VTAC
VARIABLE
CLOSING
TIME
Automatic closing time variable in relation of pedestrian traffic. Choose between the following values:
NO = disable
YES = enable
Setting the manual friction of the door (only with power supply), by means of the electrical
connection of the motor windings. Choose between the following values:
OC = manual door opening without friction (motor with open circuit windings)
SC = manual door opening with friction (motor with short-circuit windings)