FA00150-EN v.7 - 06/2017
34
CAME S.p.A.
Display
Description
Factory settings
FW
FIRMWARE
UPGRADE
Programming procedure of function selector.
Insert the micro SD memory in the electronic control.
From this menu, choose the firmware version you want.
Press ENTER until it starts the programming procedure that lasts about 30 seconds, at the end the
display shows "SAVE".
After the procedure, remove the micro SD memory from the electronic control and store it for future
use.
Note: in the case of programming error or missing firmware (W103), proceed as follows: disconnect
the power supply, insert the micro SD memory, give power supply, and repeat the programming
procedure from this menu.
- - - -
VER
VERSION
Displaying the firmware version of function selector (eg = 0200).
- - - -
TIN
TAG INPUT
You can upload the badges and numeric codes used in another automation, already stored in the
micro SD memory. Choose between the following values:
NO = no upload
YES = upload the badges and numeric codes from the micro SD memory
NO
TOUT
TAG OUTPUT
You can save the stored badges and numeric codes in the micro SD memory. Choose between the
following values:
NO = no save
YES = save the stored badges and numeric codes in the micro SD memory
NO
STCL
CLOSED
DOOR
SIGNAL
Set the signaling of closed and locked door, with bistable locking device and microswitch. Choose
from the following values:
NO = the symbol "closed door" remains lit even if the door is opened by hand.
YES = the symbol "closed door" lights up only when the door is really closed and locked.
Note: if the locking device does not close the door, the symbol "closed door" flashes.
NO
13.5 INFORMATION AND DIAGNOSTICS MENU
Using the buttons ↑ and ↓ select INFO, press ENTER to select and adjust the following information and diagnostics menu.
Display
Description
Factory settings
SHOW
DISPLAY
INFO
Displaying information of warning and faults. Choose between the following values:
CONT = the display shows the active contacts of the terminal blocks and the alarms.
WARN = the display shows the alarms only.
CONT
VER
VERSION
Displaying the firmware version of electronic control (eg = 0200).
- - - -
CYCL
CYCLES
Shows the number of cycles of the door (1 = 1.000 cycles, 9000 = 9.000.000 cycles).
0000
SERV
SERVICE
SIGNAL
Enabling the signaling of routine maintenance of the door.
NO = no signaling
1 = 1.000 cycles / 9000 = 9.000.000 cycles
0000
LOG
INFO
OUTPUT
You can save the following information in the micro SD memory (sliding_log.txt): the last 20 warnings,
the menu settings, and the electronic devices connected to automation. Choose between the
following values:
NO = no save
YES = save the information in the micro SD memory
NO
WARN
WARNING
LIST
Displaying of the last 10 warnings (the warning number 0 is the last):
0.xxx / 1.xxx / 2.xxx / 3.xxx / 4.xxx / 5.xxx / 6.xxx / 7.xxx / 8.xxx / 9.xxx
0. - - -