It is possible to create master badge and master numeric code that allows the saving of the badges
and the numeric codes, without the use of the menu. Choose from the following values.
NO = no saving
MMOD = creation of the master badge and master numeric code to saving badges and numeric codes
for function selector activation: proceed as SMOD.
MOPE = creation of the master badge and master numeric code to saving the badges and numeric
codes of opening priority: proceed as SMOD.
Note: if the badge and the numeric code is not recognized the display shows the message UNKN, or if
the badge and the numeric code is already stored will show the message NOK.
- The use of the master badge is the following:
- approach the master badge to the function selector (in front of the NFC symbol), the buzzer emits 2
beeps at the beginning of the storage procedure,
- approach the badges, that you want to store, one at a time, to the function selector (in front of the
NFC symbol), the buzzer emits 1 beep of confirmation storage,
- wait for 20 seconds, the buzzer emits 2 beeps at the end of the storage procedure.
Note: if the badge and the numeric code is not stored, the buzzer emits no beeps.
First setting of function selector, when the 1-G1 (1-G2) contact becomes closed. Set the menu ADV >
STG1 (STG2) > SAM.
Connect the contact of a clock to 1-G1 (1-G2) terminals, and choose between the following values:
OPEN = open door
AUTO = automatic bi-directional operation
CLOS = closed door
EMERGENCY - In case of Emergency automation, the "closed door" setting must be made only by the
function selector.
1D = automatic one-way operation
PA = automatic partial operation
1DPA = automatic one-way operation and partial
Second setting of function selector, when the 1-G1 (1-G2) contact becomes open. Set the menu ADV
> STG1 (STG2) > SAM.
Connect the contact of a clock to 1-G1 (1-G2) terminals, and choose between the following values:
OPEN = open door
AUTO = automatic bi-directional operation
CLOS = closed door
EMERGENCY - In case of Emergency automation, the "closed door" setting must be made only by the
function selector.
1D = automatic one-way operation
PA = automatic partial operation
1DPA = automatic one-way operation and partial