p.
8
8 - Manual code:
FA00028-EN
FA00028-EN v.
1
- 05/2015 - © Came S.p.A. The data and information in this manual may be changed at any time and without notice.
⚠
For installing and balancing the G03001 boom, read the documentation for the G03003 accessory.
For the G03002 boom, read the documentation for the G03004 accessory.
FUSE TABLE ZL30
- Line
5 A-F (120 V)
3.15 A-F (230 V)
- Card
1 A-F
- Gearmotor
15 A-F
- Accessories
2 A-F
ELECTRICAL CONNECTIONS
Warning! Before working on the control panel, cut off the main current supply and, if present, remove any batteries.
Power supply to the control panel and control devices: 24 V AC/DC.
Functions on input and output contacts and time and user management details, are set up and viewable on the control panel's display.All connections
are quick-fuse protected.
Description of parts
1. Motor fuse
2. Accessories fuse
3. Control board fuse
4. Transformer terminal boards
5. AF card connector
6. Programming buttons
7. Programming warning LED
8. Power supply on warning LED
9. Gearmotor terminal
10. Terminals for control and safety devices
11. Display
The cabinet should be installed with the inspection hatch on the most accessible side to make any adjusting easier.