The CAME ÖZAK G6000T is an automatic barrier from the GARD series, designed for controlling access in various environments. This "partly-completed machinery," as defined by Directive 2006/42/CE, is intended for integration into larger automation systems and must be installed by expert, qualified staff in compliance with European Directive 2006/42/CE and applicable European standards.
Function Description:
The G6000T automatic barrier is designed to regulate vehicle and, in some configurations, pedestrian access in private and public parking facilities, residential areas, or high-traffic volume zones. It operates by raising and lowering a barrier boom to permit or deny passage. The system can be configured for various operational modes, including automatic closing, open-only, open-close-invert, and close-only functions, controlled via buttons, keypads, transponder selectors, or transmitters. Safety features such as photocells are integrated to detect obstructions and prevent accidents. The barrier's movement speed and deceleration can be adjusted, and it includes a braking action during closing for enhanced control. The system supports a paired connection with a single command, allowing one barrier to act as a MASTER and pilot a SLAVE barrier, enabling synchronized operation for wider passages.
Important Technical Specifications:
- Model: G6000T
- Maximum Clearance Width of the Passage: 6.5 meters
- Protection Rating (IP): 54
- Power Supply: 230 V AC - 50/60 Hz
- Input Voltage Motor: 24 V DC
- Max Draw: 15 A
- Power: 300 W
- Torque: 600 Nm
- Opening Time: 4 to 8 seconds
- Duty Cycle: Intensive Service
- Operating Temperature: -20 to +55 °C
- Reduction Ratio: 1/202
- Apparatus Class: I
- Weight: 72 kg
- Dimensions (Cabinet): 460 mm (width) x 240 mm (depth) x 1077 mm (height)
- Control Board: ZL38, with quick-fuse protection for all wiring connections.
- Fuses: Line (3.15 A-F), Control Board (630 mA-F), Motor (10 A-F), Accessories (2 A-F).
- Radio Control: Compatible with TOP and TAM series transmitters (433.92 MHz) using AF43S or AF868 cards.
- Cable Types: H05RN-F (outdoors, 230V), H05VV-F (indoors, 230V), FROR 20-22 II (up to 48V). RG58 for antenna connection.
Usage Features:
- Configurable Operation: DIP switches on the control board allow for customization of functions such as automatic closing, open-only, open-close-invert, close-only, pre-flashing, obstruction detection, slave motor piloting, immediate closing, total stop, and braking action.
- Adjustable Sensitivity: The SENS trimmer allows adjustment of obstruction detection sensitivity during boom movement.
- Automatic Closing Time (A.C.T.): The A.C.T. trimmer adjusts the waiting time (1 to 120 seconds) before the barrier automatically closes after opening.
- Speed Adjustment: Travel speed (Min, Med, Max) and slow-down speed (Min, Max) can be regulated via fastons on the control board.
- Manual Release: The barrier can be manually unlocked using a customized key for inspection or in case of power failure.
- Signaling Devices: Outputs for barrier state notification (24 V AC - 3 W max) and flashing lights (24 V - 32 W max) are available to indicate movement or status.
- Safety Devices: NC contact inputs for photocells (C1 and C5) provide safety functions. C1 enables reopening while closing upon obstruction, and C5 facilitates immediate closing after a vehicle passes.
- Paired Connection: Supports master-slave configuration for controlling two barriers simultaneously with a single command, ideal for wider entrances.
Maintenance Features:
- Balancing the Boom: The barrier is supplied with two Ø 50 mm springs (001G04060) for balancing. Depending on the boom's configuration, one or both springs may be used. The balancing procedure involves releasing the gearmotor, loosening the rod nut, manually adjusting spring tension until the boom stabilizes at 45°, then re-fastening the nut and locking the gearmotor. Springs should be lubricated with spray grease after adjustment.
- Limit-Switch Adjustment: Mechanical stops and an adjustable transmission rod allow for precise setting of the boom's vertical (open) and horizontal (closed) positions. This process requires powering up the system with the inspection hatch closed.
- Troubleshooting Guide: The manual provides a comprehensive troubleshooting table linking common problems (e.g., barrier not opening/closing, photocells not working, boom starting slow) to specific references and checks, aiding in quick diagnosis and resolution.
- Fuse Replacement: All wiring connections are quick-fuse protected, making fuse replacement straightforward for various components (line, control board, motor, accessories).
- Component Access: The cabinet design allows access to internal components, including the control panel, gearmotor, and balancing springs, for installation, adjustment, and maintenance.
- Environmental Considerations: The product is designed for dismantling and disposal in an environmentally responsible manner, with components categorized for recycling (aluminum, plastic, iron, electrical cables) or specialized disposal (control boards, batteries, transmitters) by certified professional services.