CAMPO EQUIPMENT CO. LTD. (ECOBLAZE)
6 Carson Court, Brampton, ON, CANADA, L6T 4P8
Tel: (905) 793-2525 | Fax: (905) 793-8768 | www.campoequipment.com
pg. 1
NG/LP DIRECT FIRED SPACE HEATER: BLAZE DF1600
WWW.CAMPOEQUIPMENT.COM
REPORT # 0367GH009S
Installation Instructions-Manual-Maintenance-Parts List
CAUTION: DO NOT TAMPER WITH HEATER OR ITS CONTROLS. CALL A QUALIFIED SERVICE TECHNICIAN
Retain manual for future reference May 19, 2021
CERTIFIED FOR USE IN CANADA AND THE U.S.A.

Questions and Answers

  • T
    Thomas BrownAug 12, 2025
    Why does my Campo Equipment ECOBlaze DF1600 burner stop during usage?
    • T
      Terry StewartAug 12, 2025
      The burner might stop during usage due to several reasons. The heater may be overheating, so check if the modulating valve is stuck. There might have been a power interruption, so restore power. Finally, the gas burner ports could be obstructed; in this case, clean or replace the burner.
  • H
    Henry StevensAug 27, 2025
    How to troubleshoot overheating in Campo Equipment ECOBlaze DF1600 Heater?
    • A
      Amber NelsonAug 27, 2025
      If your Campo Equipment Heater is overheating, it could be due to excessive gas pressure. Try adjusting or replacing the regulator. Another possibility is a defective RTC discharge temperature sensor, which would require replacing the sensor and troubleshooting the modulation system.
  • G
    Gerald WoodSep 3, 2025
    What to do if Campo Equipment ECOBlaze DF1600 blower motor does not run?
    • W
      Wayne BirdSep 3, 2025
      If the blower motor on your Campo Equipment Heater isn't running in blower mode, it could be due to several reasons. First, ensure there is current to the heater by turning the breaker or safety switch ON. Check that the incoming voltage is sufficient. Inspect the wiring connections for disconnections, looseness, or breaks; connect, tighten, or replace the wiring connections as needed. Verify that the main switch is ON and not defective; turn the control toggle switch ON or replace the switch. Lastly, check the VFD to see if there is power to it.
  • D
    David BakerNov 18, 2025
    What to do if Campo Equipment Heater burner does not ignite?
    • R
      rachel44Nov 18, 2025
      If the burner on your Campo Equipment Heater doesn't ignite, there are several potential causes. Check the incoming voltage to ensure it's sufficient. Inspect the electrode for disconnections, incorrect adjustments, or defects; connect, adjust, or replace it as needed. Examine the air proving switch for disconnections or defects, and connect or replace it. Verify the tilt switch is connected, the unit is on a level surface, and that the switch isn't defective; connect or replace the tilt switch, or level the unit. Check if the fan overheat switch is open. Ensure sufficient gas delivery by filling the tank, opening valves, or replacing solenoid valves. Adjust or replace the regulators if they are incorrectly adjusted or defective. Clean obstructed burner gas ports or replace the burner if d...