Critical warning about fire/explosion risk if instructions are not followed.
Emergency procedure for gas leaks, emphasizing immediate action and contacting authorities.
Details the step-by-step operational sequence of the Dynaforce® appliance.
Specifies minimum clearances required from combustible materials for safe installation.
Critical safety warning against installing near flammable vapors.
Emphasizes reading the manual and using qualified technicians for installation and service.
General safety warning regarding installation, adjustment, and maintenance.
Guidelines for selecting a proper location and procedure for unit installation.
Provides general guidelines for venting the appliance safely and effectively.
Lists approved materials for exhaust vents and intake air piping.
Requirements for conventional indoor venting installations.
Instructions for sidewall venting installations, including length and elbow considerations.
Critical danger warning against using specific prohibited venting materials.
Specifies required clearances for vent terminals to prevent hazards and ensure proper operation.
Critical caution regarding negative pressure in the mechanical room.
General requirements for connecting the gas supply to the appliance.
Explains the function and types of air/gas ratio control valves used.
Procedure for checking the gas supply pressure to the appliance.
Details how differential air pressure operates the appliance and measurement points.
Specifies required regulated gas supply pressures and lockup pressure limits.
Warning about potential issues when connecting to chilled water systems.
Safety caution regarding hot discharge water from the relief valve.
Critical caution for working with high voltage circuits, emphasizing safety precautions.
Lists and describes all possible error codes and their meanings.
Final steps for commissioning the appliance after adjustments.
Detailed procedure for adjusting gas valve settings for proper combustion.
Troubleshooting steps when flame disappears during operation.
Troubleshooting for Delta-T limit trips and temperature differences.
Troubleshooting for issues where flame detection is out of sync.
Troubleshooting for internal fault errors.
Comprehensive troubleshooting for flame failure issues.
Caution to keep appliance clear from combustible materials.
Safety warning before starting the boiler, checking for gas odors.
Caution regarding temperature adjustments at less than 100% input.
Warning about the nature of the control and interface drawing.