Menu - 3 - Boiler options
DISPLAY
ACTION CONFIGURATION
S
ection Digit 1 Digit 2 and 3
U
nder floor heating system 0
0 :
no
1 : yes
Factory
setting
once
x times
Menu - 4 - Boiler settings
Section Digit Digit
1 2 and 3
Room thermostat operation 0 0 : Burner only
0 1 : Burner and pump
Pump speed 1 0 : High speed
1 1 : Low speed
Pump post circulation duration 2 0.0 min
From 0 to 5 minutes by step of 0.5 min. 2 0.5 min
2 1.0 min
2 5.0 min
Maximum Central Heating flow temperature 4 50°C
4 80°C
CH anti cycling delay 8 0.0 min
From 0 to 7 minutes by step of 0.5 min. 8 0.5 min
8 2.5 min
8 5.0 min
CH maximum output limitation
Model 24
From step 0 (P. min.) 8 kW Value from
to step 10 (P. max.) 24 kW 9 0 to 10
Model 30
From step 0 (P. min.) 9 kW Value from
to step 10 (P. max.) 28 kW 9 0 to 10
Factory
setting
D
ISPLAY
ACTION CONFIGURATION
once
x times