EN
7
Connec
t the water hose to the water
suppl
y tap (fig. 3) only using the hose
suppl
ied with the appliance (do not
reus
e old hose-sets).
Som
e models may include one or more of
th
e following features:
HOT&
COLD (fig. 4):
water mains connection settings with hot
and cold water for higher energy savings.
Connec
t the grey tube to the cold water
ta
p
and the r
ed one to the hot water
ta
p. The machine can be connected to
the cold water tap only: in this case, some
programs may start a few minutes later.
AQ
UASTOP (fig. 5):
a device located on the supply tube that
stops water flow if the tube deteriorates;
in this case, a red mark will appear in the
window “A” and the tube must be
replaced. To unscrew the nut, press the
one-way lock device "B".
AQ
UAPROTECT – SUPPLY TUBE WITH
GUARD (fig. 6):
Should water leak from the primary
internal tube "A", the transparent
containment sheath "B" will contain water
to permit the washing cycle to complete.
At the end of the cycle, contact the
Customer Service Centre to replace the
supply tube.
The was
hing machine should be installed
in its final position such that the water fill
hose is not kinked or trapped. The
corrugated drain hose should be inserted
into suitable drain pipe of between 50 cm
and 85 cm height above the floor using
th
e curved drain hose support. If an under
si
nk connection is used the drain hose
must be routed above the sink overfill
opening to prevent back siphoning. Care
must be taken to avoid kinking or trapping
the drain hose (fig. 7).
3
1
4
B
A
5
B
A
6
min 50 cm
max 85 cm
+2,6 mt
max
max 100 cm
7
Hy
draulic connections
Se
tting
Re
gulate the height of the dryer
The 4 adj
ustable f eet al low t he
height of the dryer to be adj usted
from 827 mm to a maximum of
847 mm . To a
djust the height, you
should r otate the adj ustable feet,
ensuring that t he machine is lev el
(figure 1).
Note : we suggest to Put the
dryer at
the maximum height
possible in order to avoid tilting,
lefting at least 5mm from the
top of the furniture.
Before to fix the hinges it’s
necessary to determinate the
depth of the dr y
er from the front
part of the kitchen a ccordingly
with the dept of the kick plate
(check picture) and chose the
right installation option (fig
ure 2).
Option 1
T
he position of the plinth of
the dry
er is set back less than
54 mm from the front of the
furniture.
Position the template onto the
reverse of
the furniture door. It is
possible to mount the hinges and
closure magnet on the right or
left-hand side depending on your
requirements. Mark the screw
hole positions, then drill out
these positions (figure 3).
Figure 1:
Figure 2:
Option 1:
Option 2:
Figure 3:
We suggest
mounting the
furniture door so that it opens
towa
rds the left, same direction
as the porthole door.
Instructions for mounting the
furniture door
cons
ider the thickness of the
.
Regulate the height of the dr
yer
The 4 adj
ustable f eet al low t he
height of the dryer to be adj usted
from 827 mm to a max imum of
847 mm . To a
djust the height, you
should r otate the adj ustable feet,
ensuring that t he machine is lev el
(figure 1).
dryer at
the maximum height
possible in order to avoid tilting,
leaving at least 5mm from the
top of the furniture.
Before fixing the hinges it’s
necessary to
determine the
depth of the dryer from the front
part of
the kitchen according
to the depth of the kick plate
(check picture) and chose the
right installation option (f
igure 2).
Option 1
The position
of the plinth of
the dryer is set back less than
54 mm from the front of the
furniture.
Position the template onto the
reverse of the furniture door. It is
possible to mount the hinges and
closure magnet on the right or
left-hand side depending on your
requirements. Mark the screw
hole positions, then drill out
these positions (figure 3).
Figure 1:
Figure 2:
Option 1:
Option 2:
Figure 3:
Instructions for mounting the
furniture door
Note
: That distance don’t
consider the thickness of the
kickplate of the kitchen.
'R
QRWLQVWDOOWKHSURGXFWLQD
ORZ WHPSHUDWXUH URRP RU LQ D
URRPZKHUHWKHUHLVDULVNRIIURVW
RFFXUULQJ$WWHPSHUDWXUHDURXQG
IUHH]LQJ SRLQW WKH SURGXFW PD\
QRW EH DEOH WR RSHUDWH SURSHUO\
WKHUH LV D ULVN RI GDPDJH LI WKH
ZDWHULVDOORZHGWRIUHH]HLQ WKH
K\GUDXOLF FLUFXLW YDOYHV KRVHV
SXPSV )RU D EHWWHU SURGXFW
SHUIRUPDQFH WKH DPELHQW URRP
WHPSHUDWXUH PXVW EH EHWZHHQ
& 3OHDVH QRWH WKDW
RSHUDWLQJ LQ FROG FRQGLWLRQ
EHWZHHQ DQG & PLJKW
VLPSO\VRPHZDWHUFRQGHQVDWLRQ
DQGZDWHUGURSVRQIORRU
3UHYHQW LWHPV
IURP IDOOLQJ RU
FROOHFWLQJ EHKLQG WKH GU\HU DV
WKHVHPD\REVWUXFWWKHDLULQOHW
DQG RXWOHW 1(9(5 LQVWDOO WKH
GU\HUXSDJDLQVWFXUWDLQV
Ɣ
$LU2XWOHWVLQWKH%DVH
:$51,1*
7KH DSSOLDQFH
PXVWQRWEHVXSSOLHGWKURXJK
VXFKDVDWLPHURUFRQQHFWHG
WR D FLUFXLW WKDW LV UHJXODU\
VZLWFKHGRQDQGRIIE\DXWLOLW\
,I
WKHVXSSO\FRUGLVGDPDJHG
LW PXVW EH UHSODFHG E\ WKH
PDQXIDFWXUHULWVVHUYLFHDJHQWRU
VLPLODUO\ TXDOLILHG SHUVRQV LQ
RUGHUWRDYRLGDKD]DUG
7KH
SOXJVKRXOGEHDFFHVVLEOHIRU
GLVFRQQHFWLRQ DIWHU WKH DSSOLDQFH
KDVEHHQLQVWDOOHG
Ɣ
Note : we
suggest to put the
dista
nce Note: That does not