Power Flue
Cannon
FITZROY INBUILT
OPERATION INSTRUCTIONS
SERVICE INSTRUCTIONS
Gmk10030
AS4553:2008
This heater is approved for use with
Please leave instructions with the owner
Par t No: F3045
Revision P - 2010
Cannon
For service to this appliance or spare
parts contact the CANNON distributor:
email: service@sampfordixl.com.au
Sampford IXL (spare parts)
Phone: 1300 727 421
Fax: 1300 727 425
FITZROY INBUILT
Natural and Propane gases.
DON’T RISK YOUR APPLIANCE WARRANTY
ONLY A LICENSED PERSON WILL GIVE YOU A COMPIANCE
CERTIFICATE, SHOWING THAT THE WORK COMPLIES WITH
ALL THE RELEVANT STANDARDS.
AND ONLY A LICENSED PERSON WILL HAVE INSURANCE
PROTECTING THEIR WORKMANSHIP FOR 6 YEARS.
SO MAKE SURE YOU USE A LICENSED PERSON TO INSTALL
THIS APPLIANCE AND ASK FOR YOUR COMPLIANCE
CERTIFICATE TO ENSURE THE MANUFACTURERS
APPLIANCE WARRANTY WILL BE HONOURED.
Power Flue
Date installed: ...............................................................................................
Compliance Certificate No .............................................................................
Installed by: ...................................................................................................
INSTALLATION NOTES
PLEASE READ THIS MANUAL
BEFORE INSTALLING
THIS HEATER.
28
COPY RATING LABEL HERE
INSTALLATION INSTRUCTIONS
The Cannon appliance is warranted against defects in materials and
Warranty service, which includes parts and labour for the replacement or
repair of defective parts, is available through the CANNON distributor.
(Details below or on page 24).
Consumers are responsible for service persons travel outside normal
service areas (approximately seventy (70) kilometer radius from the nearest
Cannon dealers location), local transport costs, or any preventative
maintenance works as described in
Any product subjected to misuse, abuse, negligence, accident or alteration
will have its warranty voided. The defacement of serial plate will also void
warranty.
If installation is not carried out in accordance with manufacturers
instructions, this warranty may be void.
The customer must keep their Tax Invoiceas proof of purchase of this
product and compliance certificate as proof of required installation.
workmanship for a period of two (2) years from its date of original
purchase, applicable only for residential use in Australia.
this manual.
Enter the details of the date installed and the Compliance Certificate
number in the appropriate area on the rear page of this manual.

Questions and Answers

  • R
    rnguyenAug 1, 2025
    What to do if my Cannon Indoor Fireplace lights but goes into lockout?
    • S
      Steven GonzalesAug 1, 2025
      If your Cannon Indoor Fireplace lights but then goes into lockout, test the flame for the correct ionization signal. You can connect a multimeter in series with the flame rod and set the function to measure micro-amps. The module will go into lockout if the flame current sensitivity is less than 0.5 micro-amps.
  • J
    Jeffrey SmithAug 7, 2025
    Why won't my Cannon Indoor Fireplace heater start, and no indicator lamps are on?
    • H
      hallkarenAug 7, 2025
      If your Cannon Indoor Fireplace heater won't start and no indicator lamps are on, first, check that the electricity supply is correct. If the Neutral and Active wires are incorrectly connected, the control module will not function.
  • F
    ftrujilloAug 13, 2025
    What to do if there is no gas to burner in my Cannon Indoor Fireplace?
    • L
      Laura WhiteAug 13, 2025
      If there's no gas going to the burner of your Cannon Indoor Fireplace, the gas valve should open at the same time as the igniter sparks. Check the solenoid coils for continuity. Also, verify that gas pressure is present at the test point when the spark is being generated and that there is gas to the inlet of the gas control.
  • M
    Mr. Brian MedinaAug 26, 2025
    How to fix a spark that is being produced but not at the burner in my Cannon Indoor Fireplace?
    • L
      Linda DayAug 26, 2025
      If spark is being produced but not at the burner of your Cannon Indoor Fireplace, ensure spark is present between the electrode and burner. Check that the spark lead is connected into the module and check the continuity of the ht cable. Also, check that there is no short circuit to earth and spark gap is correct, the wall socket to the appliance has correct polarity, the sense electrode is in flame and the appliance is earthed correctly. Listen for a cracking sound, which indicates a misdirected spark; inspect the spark ceramic insulator for cracks.
  • J
    jeffreybrownSep 10, 2025
    Why does the fuse keep blowing in my Cannon Indoor Fireplace?
    • J
      Joshua OconnorSep 12, 2025
      If the fuse keeps blowing in your Cannon Indoor Fireplace, check the solenoid coils for signs of being shorted. Also, inspect the fan and wiring for any short circuits.

Summary

Warranty Information

Safety Warnings

Gas Leak Detection Procedure

Steps to follow immediately if a gas leak is detected from the appliance.

General Safety Precautions

Key safety precautions regarding installation, operation, and maintenance of the heater.

Regulatory Location Requirements

User Operating Instructions

Powering On and Control Functions

How to power the heater and use the ON/OFF, LOW, MEDIUM, and HIGH controls.

Ignition and Flame Sequence

Explanation of the ignition process, flame establishment, and fan operation.

Troubleshooting Guide

Spark and Ignition Issues

Diagnosing problems related to spark production and ignition failure.

Flame and Lockout Conditions

Troubleshooting flame issues, lockout conditions, and fuse blowing.

Heater Not Starting

Diagnosing why the heater will not start, including no indicator lamps.

Troubleshooting Ignition Controller

Diagnostic LED Indicators

Understanding the green and red LED indicators on the ignition controller.

Fault Code Interpretation

Interpreting fault codes for normal startup, operation, and ignition failures.

Installation Detail - Flueing

Gas Control Pressure Settings

Procedures for checking and adjusting gas pressure for Natural and Propane gas.