capacity (per pair) of 50 lbs (22.6kg).
This appliance may be installed in an open pull-
out system where the top, front, sides and back are
all open to ventilation air when the appliance is in use.
This appliance can be mounted to an open, pull-out
system that has a non-flammable/heat-resistant/
non-combustible bottom shelf/tray, as the venting for
Do not use this appliance under extended awnings.
The Capital Griddle must be installed on the
TO CONNECT THE GAS SUPPLY
This appliance shall not be located, or used, under
The griddle must be connected to the RV's propane
* A 3/8" male flare connection is provided for gas line
low pressure propane gas system precautions are
Failure to comply could result in a fire or personal
When unit is in storage (travel) position, ensure all
overhead, un-protected, combustible construction.
opposite side from the fuel distribution/dispensing
the high pressure requirements of the Standard for
in place and all propane gas shut-off valves are in
The hose must be installed in a manner that will not
griddle while in use or in the storage travel mode.
ANSI/UL 569 , and shall be of a length no longer
system of the recreational vehicle.
Pigtails and Flexible Hose Connectors for LP Gas,
in the "in use" position of its mounting system.
system with a flexible hose connector complying with
**If this appliance is removed from the RV for any use
connection. Some standards may require the use of
The Capital brand griddle is designed for installation
Drawer slides need to be rated for a minimum
allow it to come in contact with the hot surface of the
when fully extended in locked position.
minimum clearance to combustible constructions
than that required to allow the griddle to be mounted
separate from the RV's LP supply system, a separate LP
REGULATOR DESIGNED FOR THIS USE!
WITHOUT FIRST CONNECTING TO AN APPROVED LP
supplied with this appliance. Specifications for
drawer slides MUST accommodate the recommended
NOTE! If mounting telescoping drawer slides to the
hose and low-pressure regulator is required before use.
BEFORE YOU BEGIN INSTALLATION
NEVER ATTEMPT TO OPERATE THE CAPITAL GRIDDLE
a manual shut-off valve in the gas line external to the
the gas and apply soapy water to all joints to see if
that are supplied with the griddle. Using any screw
griddle base, make sure to use the self-drilling screws
STEP 10 of page 5 for Connecting the Gas Supply.
this appliance is out the back vents!
NOTE: It will be necessary to hold the flare fitting on
in permanent installation. For such instances, refer to
the griddle manifold when connecting the gas line.
base, due to improper screw use, will void the griddle
MODEL 7800 - PERMANENTLY INSTALLED
CAPITAL GRIDDLE ASSEMBLY and
INSTALLATION INSTRUCTIONS
using telescoping drawer slides. Slides are NOT
NOTE: The 7800 Series /(all models) can be installed
Never check for leaks with an open flame. Turn on
longer than 3/4" may come in contact with the internal
LP piping. Any damage to the LP pipe inside the griddle