9Instruction manual WDU050Please keep this instruction manual for future reference
DANGER:
Improper connection of the equipment-grounding conductor can result in a risk of electric
shock. Check with a qualified electrician if you are in doubt as to whether the appliance is
properly grounded.
NOTE:
Disconnect the electric power to disposer circuit before installation. Turn the circuit breaker to
the OFF position or remove the fuse.
A. Connect the disposer to220-240 Volt, 50-60 HzAC current only.
B. If a plug-in cord is used, use a three-prong plug.
A earth wire should be attached to the ground screw
in the bottom of the disposer (end bell).
Follow the lead connected to this blade marked with
a ‘L’ and attach that lead to the blue wire on the
waste disposer.
C. Use a cable clamp strain relief connector where the
power cord enters the disposer.
NOTE:
When viewing face of electrical plug with the earth pin at top, the left blade is connected to the
identified wire.
3
IIMMPPOORRTTAANNTT SSAAFFEETTYY IINNSSTTRRUUCCTTIIOONNSS..
READ ALL INSTRUCTIONS BEFORE USING.
WARNING!
Electrical connection (cont.)
If yo u are not familiar with electrical po wer and procedu res, callaqualifie d electri cian.
1. Choose a power cord not less than H05VV-F,
2. Chose a power cord not less than H05V V-F,
3G1 .0mm and f itted withaswitch, the switch
shall be directly connected to the supply
terminals and shall have a contact separation in
all poles, providing full disconnect under
overvol tage category III conditions(the full
disconn ection not less than 3mm).
3. Make sure the switch is easi
ly visible
E
EAARRTTHHIINNGG IINNSSTTRRUUCCTTIIOONNSS::
This appliance must be earthed. In the event of a
malfunction or breakdown earthing provides a
path of least resistance for the electric current to
reduce the risk of electric shock. This appliance is
equipped with a cord having a equipment earthing
conductor and earthed plug. The plug must be
plugged into a appropriate socket this is correctly
installed and earthed in accordance with the local
codes and ordinances.
D
DAANNGGEERR::
Im proper conn ection of the equipment-grounding
conductor can result ina risk
of electric shock. Check with a qualified
electrician if y ou are in doubt as to whether the
appliance is properly grounded.
N
NOOTTEE::
Disconnect the electric power to disposer circuit
before installation. Turn the circu it breaker to the
O
OFFFF position or remove the fuse.
A. C onnect the disposer to 220-240 Volt, 50-60
Hz AC current only.
B. I f a plug-in cord is used, use a th
ree-prong
plug. A earthwire should be attached to the
ground screw in the bottom of the disposer (end
bell).
2
3G1 .0mm incorporate w ith a plug rated 250V
13A (fuse in plug: 250V, 10A) approved by BSI
with matched ground wire for the UK market
(Standard: BS1363-1) or a plug rated 250V 16A
app rove d by VDE with match ed ground wire
(Standard: DIN VDE 062 0-1).
The power cord and/or connections must
comply with l ocal codes and ordinances.
FFoorr
MMooddeellss NNoott
EEqquuiippppeedd ww iitthh aa
CCoorrdd::
and acc essible. The recommend distance
between this appliance and
electrical switch is
within 2m.
TToo aattttaacchh aa
ppooww eerr cc oorrdd::
2
To wire your disposer directly into the mains:
GROUNDING INSTRUCTIONS:
This appliance must be connected to a grounded, metal,
permanent wiring system, or an equipmentgrounding
conductor must be run with the circuit conductors and
connected to the equipmentgrounding terminal or lead
on the appliance.
A. If you use BX cable:
1. These products are designed for household use.
2. Connect a line wire to blue lead of disposer with a wire
nut. Connect theneutral wire to thebrown lead of
disposer with a wire nut. Connect the bar
e ground wire
to the ground screw. The ground wire should be clamped
and held by a strain relief bracket.
3. Do not usearigid conduit for the wiring connection.
4. A dedicated acceptable motor switch, with the off
position marked, shall be provided for this disposer at the
time of installation (not included). The switch shall be
mounted in sight of the disposer or the
sink opening for the disposer.
If BX cable is not used, provideaseparate ground wire
to thenearest reliable ground, using the screw in the
end bell for the ground wire.
Follow the lead connected to this blade marked with
a 'L'
and attach
that
le ad to the blue wire on the
waste disposer.
NNOOTTEE::
When viewing
face of electrical plug
with the earth pin
at top, the left blade
is connected to the
identified wire.
Strain Relief bracket
C. Us e a c able clamp strain
re lief connector where the
power cor d enters the
dispo ser.
Nut
Red reset b utton
Gro und screw
Wir e nut
Rem ove
bot tom cap
To house current
or the power cord
Bottom of the
disposer (e nd b ell)
Strain Relief bracket
Nut