Quick Reference Guide
Loading and Rinsing of the Kangaroo™ ePump
Enteral Feeding Pump
Quick Reference Guide
A. Feed and ush valve assembly
B. Feed only valve assembly
C. Distal end of feeding set
D. Pump
Proper Rinsing of Feeding Set
Proper Loading and Unloading of Feeding Pump
Grasp thumb tab on valve
and insert firmly into left
pocket, ensure valve is fully
seated. Tab should align
with raised white line on left.
Grasp black ring retainer,
gently wrap tubing around
rotor and insert retainer
directly into right pocket.
Do not overstretch tubing.
To properly unload a pump
set, power the pump off
and wait 10 seconds before
removing the feeding set.
18 in.
(46 cm)
Disconnect feeding set
from patient before rinsing.
The feeding set must
remain loaded during the
rinsing procedure.
CAUTION – if set is
removed from the pump
while in operation, it
may damage the set and
prevent use, and will
negatively impact the
system accuracy.
Empty contents of feed bag. Fill the feed bag with water
to approximately half of
the total capacity. Properly
seal the bag and shake for
5 to 10 seconds.
Empty the feed bag and
repeat the last step until the
bag contains clean water.
Power the pump on. Select
“Keep Settings” to continue
with previous setting or
“Clear Settings” to start
programming new pump
settings.
Press the “Prime Pump
button to enter the
“Prime Pump screen.
Press and hold the
“Hold to Prime button
until only clean water
flows through the tubing.
Once the rotor starts this,
it takes between 1 and 2
minutes.
Empty bag of water. Prime
to remove any remaining
water out of the feeding set.
CAUTION – To achieve
proper accuracy, the bottom
of the feeding set bag must
be 18 in. (46 cm) above the
top of the feeding pump.
1 2 3
1 2 3 4 5
6 7 8 9 10
For additional operations and information, see the Operating Manual for the programmable
Kangaroo™ ePump Enteral Feed and Flush pump.
A
B
C D