When the
+)
alarm is detected the following information, regarding the status parameters, is recorded:
temperature before the power failure;
duration of the power failure ;
time the power failure is detected (instant the power resumes );
temperature reached on resumption of power;
number of events (
+)
) detected.
In the case of a series of alarm (
+)
) events, the information on the alarm is updated:
both temperatures involve the highest value of all the events recorded;
the time refers to the last event;
the duration is the longest of all the events recorded;
the number of events is increased by 1.
$ODUPVLJQDOV
: the detection of one of the two alarm events,
+$
or
+)
, is signalled using the LED display of the plug-in
instrument, and by activating any alarm devices available on the instrument: alarm LED, buzzer if featured, alarm relay if featured.
+$DODUP
: the display LED
ó
shows the
+,
alarm code flashing
alternately with the temperature value, the alarm LED
ì
is on and the
upper segment
of the left-most digit is on.
If present the buzzer and the alarm relay are also activated.
+)DODUP
: the display LED
ó
shows the
+,
alarm code flashing
alternately with the temperature value, the alarm LED
ì
is on and the
lower segment
ú
of the left-most digit is on.
If present the buzzer and the alarm relay are also activated.
 &DQFHOOLQJWKHDODUPV
In the event of the
+$
or
+)
alarm signal, the signals can be reset,
both the signals and the recording of the status can be cancelled completely:
press the button for 2 seconds to turn off LED
ì
, silence the buzzer and deactivate the alarm relay, if present. The display
still shows the
+$
or
+)
alarm status (segments
and
ú
in the figure) and the alarm code;
use the parameter
WR
to completely cancel the pending alarms, signals and status recording variables.
Warning: resetting the signals or the entire status of alarm cancels the signals requested by the HACCP module; if other alarms
detected by the plug-in instrument are present, some signals may remain active.
ì
ó
)LJ
ú
ì
ó
)LJ