What does 'kV Limit' mean on my Carlisle Ransburg MicroPak 2e Controller?
- TTeresa HarrisSep 2, 2025
The Carlisle Controller displays 'kV Limit' when the system has exceeded the kV Limit Hi or the Max System Limit.
What does 'kV Limit' mean on my Carlisle Ransburg MicroPak 2e Controller?
The Carlisle Controller displays 'kV Limit' when the system has exceeded the kV Limit Hi or the Max System Limit.
What does 'FLT’d by Atom' mean on my Carlisle Ransburg MicroPak 2e Controller?
The Carlisle Controller shows 'FLT’d by Atom' when an atomizer fault has caused the high voltage controller to stop.
What causes a 'Comm Timeout' error on the Carlisle Ransburg MicroPak 2e Controller?
The 'Comm Timeout' error on the Carlisle Controller means that either the MP2e or the “originating” Ethernet/IP controller failed to receive a message for three update intervals, so the connection was dropped.
What does 'Current Cable' mean on my Carlisle Ransburg MicroPak 2e?
The 'Current Cable' error on the Carlisle Controller indicates that the system has detected a loss of the Current Feedback signal from a Consolidated cascade.
What does 'Voltage Cable' mean on a Carlisle Ransburg MicroPak 2e Controller?
The 'Voltage Cable' error on the Carlisle Controller indicates that the system has detected a loss of the High Voltage Feedback signal from a Consolidated cascade.
What does 'MAX KV' mean on my Carlisle Ransburg MicroPak 2e?
The 'MAX KV' error on the Carlisle Controller means that the system has raised the Variable Voltage Output to the system maximum, but could not reach the setpoint.
What causes the 'Remote Stop' error on a Carlisle Ransburg MicroPak 2e Controller?
The 'Remote Stop' error on the Carlisle Controller indicates that the Remote Stop input circuit has been opened.
What does 'Interlock' mean on my Carlisle Controller?
The Carlisle Controller shows an 'Interlock' error when one of the enabled interlock input circuits is broken, meaning the circuit has been opened.
What does 'Over Current' mean on my Carlisle Controller?
Voltage | 100-240 VAC |
---|---|
Frequency | 50/60 Hz |
Output Voltage | 0-100 kV |
Output Current | 0-100 μA |
Control Signal | 0-10 VDC |
Operating Temperature | 0-40°C |
Storage Temperature | -20 to 60 °C |
Weight | 1.4 kg (3 lbs) |
Details essential safety measures and warnings for operating Ransburg electrostatic coating systems.
Overview of the MicroPak 2e controller's features, safety protections, and front panel displays.
Technical specifications including environmental, physical, power, and electrical requirements.
Explains the password system for Config, System, and User levels to prevent unauthorized access.
Details the front panel layout, including LEDs, switches, buttons, and their functions.
Provides guidance on general installation, product placement, and physical mounting procedures.
Details input power supply requirements, Ethernet connectivity, and output connections to cascades.
Addresses electrical noise considerations and the setup of interlock connections for system integration.
Covers initial start-up procedures, software version checks, and menu navigation basics.
Details various configuration options and diagnostic screens available on the controller.
Explains key operating parameters like voltage/current setpoints, limits, and sensitivity settings.
Describes system status, control conditions, and how faults affect operation.
Details the Ethernet/IP interface, including input/output definitions and data mapping.
Overview of the Atomizer Controller's capabilities, specifications, I/O, and speed control.
Covers operational modes, configuration, automatic shutdown, interfacing, and Ethernet/IP details.
Overview of the Discrete IO Controller's purpose, specifications, and control capabilities.
Details operational modes, input scaling, hardware signals, and I/O logic for the Discrete IO Controller.
Provides guidelines for DIP switch settings, controller connections, and general integration advice.
Offers guidance for diagnosing and resolving faults and warnings encountered during operation.
Lists part numbers and descriptions for the MicroPak 2e High Voltage Controller components.
Details the sequence of screens and parameter settings required during initial unit setup.
Summarizes the changes and updates made in this revision of the manual.