Carpigiani K 3 User’s guide
This manual is for the exclusive use of licensees and employees of McDonald’s Systems Inc Page 11 of 63
Version 5: October 2012
1.2.6 AUTOMATIC PASTEURISATION CYCLE
The machine has been pre-set in the factory to start automatically the pasteurisation cycle every night at 2
am. (the automatic pasteurisation time can be re-set at a different time by a trained technician.
1.2.7 TEMPERATURE CONTROL
When the machine is set to STOP, the tank temperature is controlled: if it is higher or equal to 59°F (15°C),
the execution of the pasteurisation program is forced. So, by pressing the PROD. button, the
pasteurisation program will automatically start.
NOTE:
After the machine’s brush cleaning, it is necessary to press the PROD. button within 60 minutes after the
front lid closing. During this 60 minutes the test at 59°F (15°C) is masked and Production is accepted. After
60 minutes, the machine does not accept the PROD. button any more and it sets to pasteurisation
function.
1.2.8 TANK LIDS HOLDER
When you need to refill the mix tank, lift the lid and turn it upside down. Insert the handle of the lid in the
slot of the holder placed on the other lid. You need not to remove the holder.
LID HOLDER