EasyManua.ls Logo

Carpigiani K3 - Monthly Cleaning; 7.1 Clean Mesh Filters (Only for Air Cooled Version)

Carpigiani K3
63 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Carpigiani K 3 User’s guide
This manual is for the exclusive use of licensees and employees of McDonald’s Systems Inc Page 55 of 63
Version 5: October 2012
7. MONTHLY CLEANING
7.1 CLEAN MESH FILTERS (ONLY FOR AIR COOLED VERSION)
It is necessary to clean the air filter every month, as follows:
step 1
Locate and remove the filter from the equipment (see fig.).
step 2
At the back sink, prepare a warm solution of McD All Purpose Super Concentrate (APSC) (HCS) using
the meter placed on the sink.
step 3
Wash the filter thoroughly in the warm McD All Purpose Super Concentrate (APSC) (HCS) solution.
step 4
After having washed the mesh filter, rinse it thoroughly using the hot water from the hose at the back
sink.
NOTE: Flush in the opposite direction to normal air flow direction in the filter.
step 5
Shake all the water off the filter.
step 6
Using a clean, sanitized towel, wipe out any remaining moisture from the filter.
step 7
Place the filter into the filter’s track.
step 8
Push the filter in until it is seated.
step 9
Cleaning of the mesh filter is completed.
CAUTION
Never use sharp metal objects to execute this operation;
a regular operation of the freezing system mostly depends on condenser cleanout.