DETAILED COOLING CAPACITIES
#
CONTINUED
EVAPORATOR AIR
CONDENSER ENTERING AIR TEMPERATURES ° F C)
75 (23.9) 85 (29.4) 95 (35) 105 (40.6) 115 (46.1) 125 (51.7)
CFM
EWB
°F(°C)
Capacity MBtuh
Tota l
System
KW**
Capacity MBtuh
Tota l
System
KW**
Capacity MBtuh
Tota l
System
KW**
Capacity MBtuh
Tota l
System
KW**
Capacity MBtuh
Tota l
System
KW**
Capacity MBtuh
Tota l
System
KW**
Tota l Sens‡ Tota l Sens‡ To t a l Sens‡ To t al Sens‡ Tot a l Sens‡ Tot a l Sens‡
25HBC560A**30 Outdoor Section With FX4DNF061 Indoor Section
1750
72 (22.2) 69.17 35.96 3.81 65.83 34.68 4.20 62.32 33.37 4.63 58.60 31.99 5.12 54.63 30.54 5.68 50.41 29.02 6.30
67 (19.4) 63.19 44.51 3.74 60.19 43.24 4.13 57.00 41.92 4.56 53.63 40.55 5.05 50.02 39.09 5.61 46.18 37.54 6.25
63 (17.2)†† 58.86 42.93 3.69 56.08 41.67 4.08 53.14 40.35 4.51 50.02 38.98 5.00 46.68 37.53 5.56 43.12 35.99 6.21
62 (16.7) 57.71 52.83 3.68 55.03 51.53 4.07 52.20 50.14 4.50 49.23 48.59 4.99 46.32 46.32 5.56 43.40 43.40 6.21
57 (13.9) 55.78 55.78 3.66 53.67 53.67 4.05 51.40 51.40 4.49 48.93 48.93 4.99 46.26 46.26 5.56 43.34 43.34 6.21
2000
72 (22.2) 70.36 37.71 3.89 66.90 36.42 4.28 63.21 35.07 4.71 59.35 33.67 5.20 55.24 32.20 5.75 50.87 30.66 6.38
67 (19.4) 64.35 47.38 3.82 61.20 46.09 4.21 57.88 44.75 4.64 54.36 43.33 5.13 50.63 41.84 5.69 46.66 40.25 6.32
63 (17.2)†† 59.99 45.61 3.77 57.09 44.32 4.15 54.01 42.98 4.59 50.76 41.57 5.08 47.31 40.08 5.64 43.61 38.48 6.28
62 (16.7) 58.97 56.64 3.76 56.19 55.19 4.15 53.39 53.39 4.58 50.73 50.73 5.08 47.86 47.86 5.65 44.74 44.74 6.30
57 (13.9) 58.06 58.06 3.75 55.76 55.76 4.14 53.31 53.31 4.58 50.67 50.67 5.08 47.80 47.80 5.65 44.69 44.69 6.29
2250
72 (22.2) 71.26 39.37 3.97 67.65 38.06 4.36 63.86 36.70 4.79 59.89 35.28 5.27 55.65 33.79 5.82 51.19 32.24 6.45
67 (19.4) 65.22 50.14 3.89 61.95 48.81 4.28 58.50 47.43 4.71 54.89 45.99 5.20 51.06 44.45 5.76 47.00 42.79 6.39
63 (17.2)†† 60.84 48.17 3.84 57.83 46.84 4.23 54.65 45.48 4.66 51.31 44.03 5.15 47.75 42.48 5.71 43.99 40.82 6.35
62 (16.7) 60.05 60.05 3.84 57.56 57.56 4.23 54.95 54.95 4.67 52.14 52.14 5.16 49.11 49.11 5.73 45.81 45.81 6.38
57 (13.9) 59.92 59.92 3.84 57.48 57.48 4.23 54.88 54.88 4.67 52.08 52.08 5.16 49.05 49.05 5.73 45.76 45.76 6.38
COOLING INDOOR
MODEL
CAPACITY POWER FURNACE MODEL
*FX4DN(B,F)061 1.00 1.00
FB4CNF060 0.97 1.06
FE4ANB006 0.99 0.99
FV4BNB006 0.99 0.99
FV4CNB006 0.99 0.99
FX4CN(B,F)060 0.99 1.03
FY4ANB060 0.98 1.07
FY5BNB060 0.98 1.07
CAP**6021A** 0.97 1.06
CAP**6024A** 0.97 1.06
CAP**6025A** 0.97 1.06
CNPH*6024A** 0.97 1.06
CNPH*6124A** 0.98 1.07
CNPV*6024A** 0.97 1.06
CNPV*6124A** 0.99 1.08
CSPH*6012A** 0.97 1.06
CAP**6021A** 0.97 1.06 58CV(A,X)110--- 20
CNPH*6024A** 0.97 1.06 58CV(A,X)110--- 20
CNPH*6124A** 0.98 1.07 58CV(A,X)110--- 20
CSPH*6012A** 0.98 1.07 58CV(A,X)110--- 20
CAP**6024A** 0.97 1.01 58CV(A,X)135--- 22
CNPH*6024A** 0.97 1.01 58CV(A,X)135--- 22
CNPH*6124A** 0.98 1.02 58CV(A,X)135--- 22
CNPV*6024A** 0.97 1.01 58CV(A,X)135--- 22
CNPV*6124A** 0.99 1.03 58CV(A,X)135--- 22
CSPH*6012A** 0.98 1.02 58CV(A,X)135--- 22
CAP**6024A** 0.98 1.02 58CV(A,X)155--- 22
COOLING INDOOR
MODEL
CAPACITY POWER FURNACE MODEL
CNPH*6024A** 0.98 1.02 58CV(A,X)155--- 22
CNPH*6124A** 0.98 1.02 58CV(A,X)155--- 22
CNPV*6024A** 0.98 1.02 58CV(A,X)155--- 22
CNPV*6124A** 0.99 1.03 58CV(A,X)155--- 22
CSPH*6012A** 0.98 1.02 58CV(A,X)155--- 22
CAP**6025A** 0.97 1.06 58HDV100--- ---20
CNPH*6024A** 0.96 1.05 58ME(B,C)080--- 16
CSPH*6012A** 0.97 1.06 58ME(B,C)080--- 16
CAP**6021A** 0.97 1.01 58ME(B,C)100--- 20
CNPH*6024A** 0.97 1.01 58ME(B,C)100--- 20
CNPH*6124A** 0.97 1.01 58ME(B,C)100--- 20
CSPH*6012A** 0.98 1.02 58ME(B,C)100--- 20
CAP**6024A** 0.97 1.01 58ME(B,C)120--- 20
CNPH*6024A** 0.97 1.01 58ME(B,C)120--- 20
CNPH*6124A** 0.98 1.02 58ME(B,C)120--- 20
CNPV*6024A** 0.97 1.01 58ME(B,C)120--- 20
CNPV*6124A** 0.99 1.03 58ME(B,C)120--- 20
CSPH*6012A** 0.98 1.02 58ME(B,C)120--- 20
CNPV*6124A** 0.98 1.04 58MV(B,C)120---20
CSPH*6012A** 0.97 1.06 58MV(B,C)120--- 20
CAP**6021A** 0.97 1.01 58PH*110---20
CNPH*6024A** 0.97 1.01 58PH*110---20
CNPH*6124A** 0.98 1.02 58PH*110---20
CSPH*6012A** 0.98 1.02 58PH*110--- 20
CAP**6024A** 0.97 1.01 58PH*135---20
CNPH*6024A** 0.97 1.01 58PH*135---20
COOLING INDOOR
MODEL
CAPACITY POWER FURNACE MODEL
CNPH*6124A** 0.97 1.01 58PH*135---20
CNPV*6024A** 0.97 1.01 58PH*135---20
CNPV*6124A** 0.99 1.03 58PH*135---20
CSPH*6012A** 0.98 1.02 58PH*135--- 20
CAP**6021A** 0.97 1.04 59*N*A100V21**20
CAP**6024A** 0.97 1.04 59*N*A100V21**20
CAP**6025A** 0.97 1.04 59*N*A100V21**20
CNPH*6024A** 0.97 1.04 59*N*A100V21**20
CNPH*6124A** 0.97 1.04 59*N*A100V21**20
CNPV*6024A** 0.97 1.04 59*N*A100V21**20
CNPV*6124A** 0.98 1.04 59*N*A100V21**20
CSPH*6012A** 0.98 1.05 59*N*A100V21**20
CAP**6024A** 0.98 1.02 59*N*A120V24**22
CAP**6025A** 0.98 1.02 59*N*A120V24**22
CNPH*6024A** 0.98 1.02 59*N*A120V24**22
CNPH*6124A** 0.98 1.02 59*N*A120V24**22
CNPV*6024A** 0.98 1.02 59*N*A120V24**22
CNPV*6124A** 0.99 1.02 59*N*A120V24**22
CSPH*6012A** 0.98 1.02 59*N*A120V24**22
CAP**6024A** 0.98 1.02 59*P5A120E24**22
CAP**6025A** 0.98 1.02 59*P5A120E24**22
CNPH*6024A** 0.98 1.02 59*P5A120E24**22
CNPH*6124A** 0.98 1.02 59*P5A120E24**22
CNPV*6024A** 0.98 1.02 59*P5A120E24**22
CNPV*6124A** 0.99 1.02 59*P5A120E24**22
CSPH*6012A** 0.98 1.02 59*P5A120E24**22
* Tested combination.
{ The kW values include the compressor, outdoor fan motor, and indoor blower motor. The kW from supplement heaters should be added to these values to obtain total system kilowatts.
} Sensible capacities shown are based on 80_F(27_C) entering air at the indoor coil. For sensible capacities at other than 80_F(27_C), deduct 835 Btuh
(245 kW) per 1000 CFM (480 L/S) of indoor coil air for each degree below 80_F(27_C), or add 835 Btuh (245 kW) per 1000 CFM (480 L/S) of indoor coil air per degree above 80_F(27_C).
# Detailed cooling capacities are based on indoor and outdoor unit at the same elevation per AHRI standard 210/240 ---2008. If additional tubing length and/or indoor unit is located above outdoor unit, a slight variation in capacity
may occur.
** System kw is total of indoor and outdoor unit kilowatts.
{{ At TVA rating indoor condition (75_F edb/63_F ewb). All other indoor air temperatures are at 80_F edb.
EWB Entering Wet Bulb
NOTE: When the required data fall between the published data, interpolation may be performed. Extrapolation is not an acceptable practice.
25HBC5