HEAT PUMP HEATING PERFORMANCE CONTINUED
INDOOR AIR
OUTDOOR COIL ENTERING AIR TEMPERATURES ° F C)
--- 3 ( --- 1 9 . 4 ) 7 ( ---13.9) 17 (---8.3) 27 ( ---2.8) 37 (2.8) 47 (8.3) 57 (13.9) 67 (19.4)
EDB
°F (°C)
CFM
Capacity MBtuh
Total
Syst.
KW†
Capacity MBtuh
Total
Syst.
KW†
Capacity MBtuh
Total
Syst.
KW†
Capacity MBtuh
Total
Syst.
KW†
Capacity MBtuh
Total
Syst.
KW†
Capacity MBtuh
Total
Syst.
KW†
Capacity MBtuh
Total
Syst.
KW†
Capacity MBtuh
Total
Syst.
KW†
Total Integ* To t a l Integ* To t a l Integ* To t a l Integ* To t a l Integ* To t a l Integ* To t a l Integ* To t a l Integ*
25HBC560A**30 Outdoor Section With FX4DNF061 Indoor Section
65
(18.3)
1750 20.70 19.04 3.28 27.02 24.83 3.42 33.72 30.75 3.56 41.23 36.62 3.72 49.82 45.33 3.93 57.86 57.86 4.12 67.41 67.41 4.34 78.26 78.26 4.58
2000 21.11 19.43 3.32 27.50 25.28 3.45 34.30 31.27 3.58 42.09 37.39 3.72 50.38 45.85 3.90 58.60 58.60 4.07 68.57 68.57 4.25 79.11 79.11 4.49
2250 21.49 19.77 3.37 27.92 25.66 3.49 34.77 31.71 3.60 43.47 38.61 3.77 50.91 46.33 3.90 59.23 59.23 4.06 69.29 69.29 4.21 79.67 79.67 4.43
70
(21.1)
1750 19.65 18.07 3.42 26.01 23.91 3.57 32.79 29.90 3.72 40.18 35.69 3.88 49.10 44.68 4.11 57.00 57.00 4.30 66.31 66.31 4.55 77.15 77.15 4.78
2000 20.06 18.45 3.46 26.49 24.34 3.59 33.34 30.39 3.73 40.83 36.26 3.88 49.67 45.20 4.08 57.72 57.72 4.26 67.32 67.32 4.46 78.01 78.01 4.68
2250 20.43 18.80 3.50 26.91 24.73 3.63 33.81 30.82 3.76 41.39 36.76 3.89 50.19 45.68 4.08 58.34 58.34 4.24 68.30 68.30 4.40 78.62 78.62 4.63
75
(23.9)
1750 18.54 17.06 3.56 24.96 22.94 3.72 31.79 28.98 3.88 39.14 34.76 4.06 48.41 44.05 4.30 56.16 56.16 4.50 65.21 65.21 4.76 76.04 76.04 4.99
2000 18.95 17.44 3.60 25.43 23.37 3.75 32.33 29.47 3.90 39.76 35.31 4.05 49.00 44.59 4.27 56.88 56.88 4.45 66.27 66.27 4.66 76.93 76.93 4.89
2250 19.32 17.77 3.65 25.85 23.76 3.79 32.79 29.90 3.92 40.31 35.80 4.06 49.45 45.00 4.26 57.47 57.47 4.43 67.20 67.20 4.61 77.54 77.54 4.83
HEATING INDOOR
MODEL
CAPACITY POWER FURNACE MODEL
*FX4DN(B,F)061 1.00 1.00
FB4CNF060 0.98 1.03
FE4ANB006 0.98 0.98
FV4BNB006 0.98 0.98
FV4CNB006 0.98 0.98
FX4CN(B,F)060 0.98 0.99
FY4ANB060 1.00 1.05
FY5BNB060 1.02 1.07
CAP**6021A** 0.99 1.04
CAP**6024A** 0.99 1.04
CAP**6025A** 0.99 1.04
CNPH*6024A** 0.99 1.04
CNPH*6124A** 0.99 1.03
CNPV*6024A** 0.99 1.04
CNPV*6124A** 0.99 1.02
CSPH*6012A** 0.99 1.03
CAP**6021A** 0.99 1.04 58CV(A,X)110--- 20
CNPH*6024A** 0.99 1.04 58CV(A,X)110--- 20
CNPH*6124A** 0.99 1.03 58CV(A,X)110--- 20
CSPH*6012A** 0.99 1.03 58CV(A,X)110--- 20
CAP**6024A** 0.99 1.03 58CV(A,X)135--- 22
CNPH*6024A** 0.99 1.03 58CV(A,X)135--- 22
CNPH*6124A** 0.99 1.02 58CV(A,X)135--- 22
CNPV*6024A** 0.99 1.03 58CV(A,X)135--- 22
CNPV*6124A** 0.99 1.00 58CV(A,X)135--- 22
CSPH*6012A** 0.99 1.02 58CV(A,X)135--- 22
CAP**6024A** 0.99 1.02 58CV(A,X)155--- 22
HEATING INDOOR
MODEL
CAPACITY POWER FURNACE MODEL
CNPH*6024A** 0.99 1.02 58CV(A,X)155--- 22
CNPH*6124A** 0.99 1.01 58CV(A,X)155--- 22
CNPV*6024A** 0.99 1.02 58CV(A,X)155--- 22
CNPV*6124A** 0.99 1.00 58CV(A,X)155--- 22
CSPH*6012A** 0.99 1.01 58CV(A,X)155--- 22
CAP**6025A** 1.02 1.08 58HDV100--- ---20
CNPH*6024A** 0.99 1.06 58ME(B,C)080--- 16
CSPH*6012A** 0.99 1.05 58ME(B,C)080--- 16
CAP**6021A** 0.99 1.04 58ME(B,C)100--- 20
CNPH*6024A** 0.99 1.04 58ME(B,C)100--- 20
CNPH*6124A** 0.99 1.03 58ME(B,C)100--- 20
CSPH*6012A** 0.99 1.02 58ME(B,C)100--- 20
CAP**6024A** 0.99 1.03 58ME(B,C)120--- 20
CNPH*6024A** 0.99 1.03 58ME(B,C)120--- 20
CNPH*6124A** 0.99 1.02 58ME(B,C)120--- 20
CNPV*6024A** 0.99 1.03 58ME(B,C)120--- 20
CNPV*6124A** 0.99 1.00 58ME(B,C)120--- 20
CSPH*6012A** 0.99 1.02 58ME(B,C)120--- 20
CNPV*6124A** 0.99 1.02 58MV(B,C)120---20
CSPH*6012A** 0.99 1.04 58MV(B,C)120--- 20
CAP**6021A** 0.99 1.03 58PH*110---20
CNPH*6024A** 0.99 1.03 58PH*110---20
CNPH*6124A** 0.99 1.02 58PH*110---20
CSPH*6012A** 0.99 1.01 58PH*110--- 20
CAP**6024A** 0.99 1.04 58PH*135---20
CNPH*6024A** 0.99 1.04 58PH*135---20
HEATING INDOOR
MODEL
CAPACITY POWER FURNACE MODEL
CNPH*6124A** 0.99 1.03 58PH*135---20
CNPV*6024A** 0.99 1.04 58PH*135---20
CNPV*6124A** 0.99 1.01 58PH*135---20
CSPH*6012A** 0.99 1.02 58PH*135--- 20
CAP**6021A** 1.01 1.09 59*N*A100V21**20
CAP**6024A** 1.01 1.08 59*N*A100V21**20
CAP**6025A** 1.01 1.08 59*N*A100V21**20
CNPH*6024A** 1.00 1.08 59*N*A100V21**20
CNPH*6124A** 1.01 1.08 59*N*A100V21**20
CNPV*6024A** 1.00 1.08 59*N*A100V21**20
CNPV*6124A** 1.01 1.06 59*N*A100V21**20
CSPH*6012A** 1.01 1.07 59*N*A100V21**20
CAP**6024A** 1.00 1.05 59*N*A120V24**22
CAP**6025A** 1.00 1.05 59*N*A120V24**22
CNPH*6024A** 1.00 1.05 59*N*A120V24**22
CNPH*6124A** 1.00 1.04 59*N*A120V24**22
CNPV*6024A** 1.00 1.05 59*N*A120V24**22
CNPV*6124A** 1.00 1.03 59*N*A120V24**22
CSPH*6012A** 1.00 1.04 59*N*A120V24**22
CAP**6024A** 1.00 1.05 59*P5A120E24**22
CAP**6025A** 1.00 1.05 59*P5A120E24**22
CNPH*6024A** 1.00 1.05 59*P5A120E24**22
CNPH*6124A** 1.00 1.04 59*P5A120E24**22
CNPV*6024A** 1.00 1.05 59*P5A120E24**22
CNPV*6124A** 1.01 1.04 59*P5A120E24**22
CSPH*6012A** 1.00 1.04 59*P5A120E24**22
NOTE: When the required data falls between the published data, interpolation may be performed. Extrapolation is not an acceptable practice.
* The Btuh heating capacity values shown are net integrated values from which the defrost effect has been subtracted. The Btuh heating from supplement heaters should be added to those values to obtain total system capacity.
{ The kW values include the compressor, outdoor fan motor, and indoor blower motor. The kW from supplement heaters should be added to these values to obtain total system kilowatts.
EDB —EnteringDryBulb