SAFETY
CONSIDERA
Installing, starting up and servicing air conditioning
equipment can be hazardous due to system pressures,
electrical components and equipment location (roofs,
elevated structures, etc).
Only trained, qualified installers and service mechanics
should install, start-up and service this equipment
Untrained personnel can perform basic maintenance
functions such as cleaning coils. All other operations
should be performed by trained service personnel.
When working on the equipment, observe precautions
in the literature and on tags, stickers and labels attached
the equipment.
Follow all safety codes.
Wear safety glasses and work gloves.
Keep quenching cloth and fire extinguisher nearby
when brazing.
Use care in handling,
equipment.
rigging and setting buky
See Table I for Physical Data.
ELECTRIC SHOCK HAZARD
Open all remote disconnecas before
servicing this equipment.
Rigging
-
Preferred method is with spreader bars from
above the unit. Use
Z-in.
(50 mm) 0-D. pipe or hooks in
lifting holes. Rig with 4 cables and spreader bars.
Al1
panels must be in place when rigging. See rigging label
on unit for details concerning shipping weights, distance
between lifting holes, center of gravity and spreader bar
dimensions. See Fig. 2.
If overhead rigging is not possible,
place
chiller on skid
or pad for rolling or dragging. When rolling, use mini-
mum 3 rollers. When dragging, pull the pad. Do not ~ppby
force ts
dtze
unif. When in final position, raise from above
to lift unit off pad.
All panels must be in
units if no skid is
supp
P
lace when rigging. Do not fork
ied.
sides only.
If unit has
skid,
truck from
r
WI-IN.
(19
mm) NOTCHES
IN END OR SPREADERS
CENTER 3F
GRAW
Fig. 2
-
Wigging with Spreader Bars
(Field Supplied)
Manufacturer reserves the right to discontinue, or change at any time, specifications or designs without notice and without incurring obligations.
PC111 Catalog No.
533-034 Printed
in
U.S.A.
Form
30GT-1
Si
Pg
i
8-aa
Replaces: New

Questions and Answers:

Carrier 30GT 030 Specifications

General IconGeneral
BrandCarrier
Model30GT 030
CategoryChiller
LanguageEnglish

Summary

Safety Considerations

Electric Shock Hazard Warning

Warning about electrical shock and the need to disconnect power before servicing the equipment.

Rigging Procedures

Detailed instructions for rigging the unit using spreader bars or other appropriate lifting methods.

Piping and Utility Connections

Power Supply and Wiring Requirements

Requirements for power supply and field wiring, including disconnects, compliance with NEC, and wire sizes.

Field Connections and Power

Main Power Connection

Instructions for connecting main power wiring from the fused disconnect switch to the unit's terminal block.

Control Power and Interlocks

Details for control power supply, including separate sources, fused disconnects, and interlock wiring.

Safety and Protection Features

Compressor Protection Mechanisms

Devices and features protecting the compressor: circuit breaker, discharge thermostat, time guard, and crankcase heater.

Cooler Freeze-Up and Safety Controls

Systems to prevent cooler freezing (heater cable) and safety cutouts for water temperature (thermostat).

Unit Control Sequence and Maintenance

Troubleshooting Guide

Compressor Not Running Issues

Common causes and remedies for the compressor failing to start or run, including power and safety device checks.

Compressor Operation Faults

Troubleshooting for issues like tripping on pressure controls, improper loading/unloading, or oil loss.