30RA 040-240 "B"
Air-Cooled Liquid Chillers with
Integrated Hydronic Module
Nominal cooling capacity 39-245 kW
50 Hz
Installation, operation and maintenance instructions
AQUASNAP
For the operation of the control please refer to
the Pro-Dialog
Control manual for the
30RA/RH - RY/RYH "B" series
Carrier is participating in the
Eurovent Certification Programme.
Products are as listed in the
Eurovent Directory of Certified
Products.
Question and Answer IconNeed help?

Do you have a question about the Carrier 30RA200B and is the answer not in the manual?

Carrier 30RA200B Specifications

General IconGeneral
Model30RA200B
CategoryChiller
TypeAir-Cooled
Cooling Capacity200 tons
RefrigerantR-410A
Compressor TypeScroll
Sound Level75 dBA

Summary

1- INTRODUCTION

1.1 - Installation Safety Considerations

Guidelines for safe installation, ensuring public inaccessibility and proper inspection procedures.

1.2 - Equipment and Components Under Pressure

Information on pressure-rated components, consulting authorities, and safety device protection.

1.3 - Maintenance Safety Considerations

Requirements for qualified personnel and safe practices during maintenance operations, including electrical safety.

1.4 - Repair Safety Considerations

Procedures for safe refrigerant handling, leak repair, and material compatibility, emphasizing technician qualifications.

2-PRELIMINARY CHECKS

6- APPLICATION DATA

7- ELECTRICAL CONNECTION

7.2 - Power Supply

Requirements for power supply voltage and phase conformity to ensure safe unit operation and warranty.

7.3 - Voltage Phase Imbalance (%)

Explains how to calculate voltage phase imbalance and the acceptable limits for safe operation.

8- RECOMMENDED WIRE SECTIONS

9- WATER CONNECTIONS

9.3 - Frost Protection

Measures and precautions for frost protection of the hydronic system components, including heaters and pump cycling.

10 - NOMINAL SYSTEM WATER FLOW CONTROL

11-START-UP

11.2 - Actual Start-Up

Guidelines for the actual start-up procedure, emphasizing supervision by qualified personnel and thermal load.

12 - MAINTENANCE

12.1 - General Maintenance of the Refrigerant Circuit

Routine cleaning and inspection of the unit's exterior and refrigerant circuit components for optimal performance.

12.2 - Refrigerant Charge

Procedures for verifying and maintaining the correct refrigerant charge (R407C) using sight-glass indicators.

12.2.3 - Recharging Liquid Refrigerant

Instructions for recharging with liquid HFC-407C, detailing its properties, leak detection, and cylinder handling.

13 - AQUASNAP MAINTENANCE PROGRAM

14 - START-UP CHECKLIST FOR 30RA LIQUID CHILLERS