Table
1
Dimensions
UNIT
38AD
38AD
024
028
38AD
034
38AD
044
38AB
054
38AB
064
38AB
084
DIMENSIONS
(Ft—in
i.)
Length
A
o
1
CO
12-10%
24-
-4
24-4
Width
B
3-11%
4-10%
6-
0‘/
4
3-11%
4-10%
6-
0%
Height
w/o
Legs
C
2-
4%
3-
r/
8
3-
2
2-
4%
3-
r/
8
3-
1%
Leg
Height
D
1-0
or
2-0
1
—6
or
2—2
1-
8
1
-4
or
2-0
1-6
or
2-2
1
_8
or
2—
Mtg
Holes
<
J
O
1
sC
o
1
0-
1%
2—%
0-
1%«
0-
1%6
0-
1%
Corner
Legs
Ik
3-
8%
3-
8%
4-
7%
5-
7%
00
1
CO
4-
7%
5-
9%
o
i
o
o
1
o
o
1
o
2-%
o
1
o
o
I
o
o
I
o
Middle
Legs
Ik
3-10
1
3-10
00
1
xr
5-
7%
CO
1
o
CO
1
XT
5~ioy
2
L
3-3%
3-
7%
6
9-4%
M
9-4%
00
o
5-3%
N
|
1
-
-
9-5%
CONNECTIONS
(in
.)
Suction
(ODM)
l-%
2-%
2-V
Liquid
(ODM)
%
7
/s
1
—%
OPENINGS
(in.)
Suction
E
2-%
4
5
(2)5
Liquid
F
1-
%
I
1-
%
1
i-
%
2
2-%
3
7/
Control
(4
holes)
G
%
1
5
4
1
k
Power
H
3-%
5
s-%
(2)3%
*Unit
38AB084
has
two
suction
connections
AIR
FLOW
GUSSET
-pf
REMOVABLE
,
n
o
.
HINGED
CONTROL
TOP
COVER
BOX
DOOR
\oNLY)
2
NI
t
Y)
REQUIRED
OVERHEAD
FL0W*\Ef/
F
/
E
Al
5
ff
ACE
38AD024
028,
034
A
^tt
w
i
Ckii
mm
'4-0
(BOTH
SIDES)
4-0
*.,
(BOTH
SIDES)"
-REMOVABLE
END
PANELS
HINGED
ACCESS
DOOR-
REQUIRED
OVERHEAD
CONTROL
BOXi
~
AIR
SPACE
AIR
FLOW
GUSSET
P"
A>
;_HINGED
POWER
:
BOX
DOOR
4-0"(BOTH
SIDES)
38AD044
4
1
-
o"——
(BOTH
SIDES)
REMOVABLE
END
PANELS
AIR
FLOW
BOTTOM
PANELREMOVABLE
REAR
OPENINGPANEL
f
Px^Removable
top
requi
Ilf(
COVER
OVER!
FLOW
AIR
SI
HINGED
AIR
control
V
box
covers
/^REMOVABLE
TOP
REQUIRED
/
COVER
OVERHEAD
^^
AIR
FLOW
AIR
SPACE
38AB054,
064,
084
O'
I?
\i
4-0
X;
(BOTH
SIDES)
'X
4
-
0
"
(BOTH
SIDES)
AIR
FLOW
THRU
CONDENSER
11
SPACE
FOR
SERVICE
AND
AIR
FLOW
Certified
dimension
drawings
are
available
on
request
Fig.
1
Dimensions
©Carrier
Corporation
1972
Form
38AD-6SI
Question and Answer IconNeed help?

Do you have a question about the Carrier 38AD024 and is the answer not in the manual?

Carrier 38AD024 Specifications

General IconGeneral
RefrigerantR-410A
Compressor TypeScroll
Phase1
Cooling Capacity24000 BTU/h
Heating Capacity24000 BTU/h
Voltage208/230V

Summary

Rigging

Skid Removal

Procedures for removing the unit's base skid.

Compressor (with coil) Section Rigging

Steps for lifting and handling the compressor section.

Coil (only) Section Rigging

Steps for lifting and handling the coil section.

Erecting and Integrating One Unit

Guidance on unit placement and assembly.

Refrigerant Piping

Piping Procedure Guidelines

Best practices for piping connections and brazing.

Wiring and Electrical Data

Control Circuit Wiring Diagrams

Wiring schematics for control circuits.

Start-Up Procedures

Preliminary Charge and System Evacuation

Steps for initial refrigerant charge and evacuation.

Service and Operation

Related product manuals