Heat pump heating performance continued
See notes on pg. 28.
INDOOR
AIR
OUTDOOR COIL ENTERING AIR TEMPERATURES
°F
3 7 17 27 37 47 57 67
Capacity
MBtuh
Total
Power
Capacity
MBtuh
Total
Power
Capacity
MBtuh
Total
Power
Capacity
MBtuh
Total
Power
Capacity
MBtuh
Total
Power
Capacity
MBtuh
Total
Power
Capacity
MBtuh
Total
Power
Capacity
MBtuh
Total
Power
EDB CFM Total Integ* kW Total Integ* kW Total Integ* kW Total Integ* kW Total Integ* kW Total Integ* kW Total Integ* kW Total Integ* kW
38BYC048-33, 34 Outdoor Section With 40FK(A,B)/FK4(C,D)NF005 Indoor Section
65
1400 22.2 20.4 2.99 26.7 24.6 3.13 31.4 28.6 3.25 36.3 32.2 3.38 42.1 38.3 3.54 48.5 48.5 3.73 56.1 56.1 3.97 64.6 64.6 4.29
1600 22.5 20.7 3.00 27.0 24.8 3.13 31.7 28.9 3.23 36.6 32.5 3.35 42.5 38.6 3.48 49.1 49.1 3.66 56.7 56.7 3.88 65.4 65.4 4.18
1800 22.7 20.9 3.02 27.2 25.0 3.13 32.0 29.1 3.23 36.9 32.8 3.33 42.8 39.0 3.46 49.5 49.5 3.62 57.2 57.2 3.83 66.0 66.0 4.12
70
1400 21.7 19.9 3.13 26.4 24.3 3.28 31.1 28.4 3.42 35.9 31.9 3.56 41.6 37.9 3.73 48.0 48.0 3.93 55.4 55.4 4.19 63.7 63.7 4.51
1600 22.0 20.2 3.14 26.7 24.5 3.28 31.4 28.6 3.40 36.3 32.2 3.53 42.0 38.2 3.67 48.5 48.5 3.85 56.0 56.0 4.09 64.5 64.5 4.40
1800 22.3 20.5 3.16 27.0 24.8 3.29 31.7 28.9 3.40 36.6 32.5 3.51 42.4 38.6 3.65 48.9 48.9 3.81 56.5 56.5 4.03 65.1 65.1 4.33
75
1400 21.1 19.4 3.26 26.0 23.9 3.43 30.8 28.1 3.60 35.6 31.6 3.75 41.2 37.5 3.93 47.5 47.5 4.14 54.7 54.7 4.41 62.9 62.9 4.75
1600 21.4 19.7 3.28 26.3 24.2 3.43 31.1 28.4 3.58 35.9 31.9 3.71 41.6 37.8 3.87 48.0 48.0 4.06 55.3 55.3 4.31 63.7 63.7 4.62
1800 21.7 20.0 3.30 26.6 24.4 3.44 31.4 28.6 3.57 36.2 32.1 3.69 41.9 38.1 3.84 48.4 48.4 4.01 55.8 55.8 4.24 64.3 64.3 4.55
Multipliers for Determining the Performance With Other Indoor Sections
Indoor
Section Size
Heating
Indoor
Section Size
Heating
Capacity Power Capacity Power
CC5A/CD5AA 060 1.00 1.10
40FK(A,B)/FK4(C,D)NB
006 1.00 0.96
CC5A/CD5AC 048 1.00 1.15
40FK(A,B)/FK4(C,D)NF
005 1.00 1.00
CC5A/CD5AW 048 1.00 1.09
COILS + 58CV(A,X)090-16 FURNACE
060 1.00 1.05 CE3AA 060 1.00 1.05
CD5AA 048 1.00 1.09
COILS + 58CV(A,X)110-22 FURNACE
CE3AA 048 1.00 1.07 CC5A/CD5AA 060 1.00 1.10
060 1.00 1.04 CE3AA 060 1.00 1.04
CF5AA 048 1.00 1.11 CK3BA 060 1.00 1.00
CK3BA 048 1.00 1.07 CK5A/CK5BA 060 1.00 1.00
060 1.00 1.02 CK5A/CK5BT 060 1.00 1.00
CK5A/CK5BA 048 1.00 1.07 CK5A/CK5BX 060 1.00 0.99
060 1.00 1.02
COILS + 58CV(A,X)135-22 FURNACE
CK5A/CK5BN 048 1.00 1.09 CC5A/CD5AA 060 1.00 1.10
060 1.00 1.01 CC5A/CD5AW 060 1.00 1.04
CK5A/CK5BT 048 1.00 1.07 CE3AA 060 1.00 1.04
060 1.00 1.02 CK3BA 060 1.00 1.00
CK5A/CK5BW 048 1.00 1.07 CK5A/CK5BA 060 1.00 1.00
CK5A/CK5BX 060 1.00 1.01 CK5A/CK5BT 060 1.00 1.00
F(A,B)4(A,B)N(F,B,C)
048 1.00 1.05 CK5A/CK5BX 060 1.00 0.99
060 1.00 1.03
COILS + 58CV(A,X)155-22 FURNACE
FB4(A,B)NB 070 1.00 0.99 CC5A/CD5AA 060 1.00 1.10
FC4(B,C)NB 054 1.00 0.98 CC5A/CD5AW 060 1.00 1.04
070 1.00 0.99 CE3AA 060 1.00 1.03
FC4(B,C)N(F,B) 048 1.00 1.05 CK3BA 060 1.00 0.99
060 1.00 1.03 CK5A/CK5BA 060 1.00 0.99
FG3AAA 048 1.00 1.07 CK5A/CK5BT 060 1.00 0.99
060 1.00 1.06 CK5A/CK5BX 060 1.00 0.99