4
Accessories
INSTALLATION INSTRUCTIONS
Note: Except the above parts provided, the other parts needed during
installation you must purchase.
●
●
This illustration is for explanation purposes only.
Copper lines must be insulated independently
Fig.3
Ensure that the space around the left and
right of the indoor unit is more than 12cm.
The indoor unit should be installed allowing
a minimum clearance of 15cm from the
ceiling.
Use a stud finder to locate studs to prevent
unnecessary damage to the wall.
A minimum pipe run of 3 metres is required
to minimise vibration & excessive noise.
The indoor unit should be installed on the
wall at a height of 2.0 metres or more from
the floor .
Two of the A, B and C directions should be
free from obstructions.
CAUTION
.
2
Seal (See Page 8 for details)
1
(See page 8 for details)
1
8
8
1
1
1
8
9
Loop the
connective
cable.
C
B
A
6
7
1
2
3
4
5
6
8
Self-tapping Screw B ST2.9X10
Remote controller
Installation Plate
Name ofAccessories
Self-tapping Screw A ST3.9X25
Drain Joint
Connecting
pipe Assembly
Clip Anchor
Number
Q ty’
9
Remote controller holder
7
Parts you must
purchase
(A minimum
pipe wall-thickness
of 0.7mm is required.)
6.35
9.52
12.7
Liquid side
Gas side
( 12000Btu/h model)<