LUV INVERTER SERIES
Service Manual
42/38LUVH025N-1
42/38LUVH035N-1
42/38LUVH045N-1
42/38LUVH055N-1
42/38LUVH065N-1
42/38LUVH075N-1

Table of Contents

Question and Answer IconNeed help?

Do you have a question about the Carrier 38LUVH035N-1 and is the answer not in the manual?

Carrier 38LUVH035N-1 Specifications

General IconGeneral
BrandCarrier
Model38LUVH035N-1
CategoryAir Conditioner
LanguageEnglish

Summary

Safety and Precautions

Safety Precaution

Instructions to prevent injury to users and property damage.

Warnings and Cautions

Critical alerts and important notes for installation, operation, and maintenance.

Outline and Dimensions

Indoor Unit Dimensions

Physical dimensions and specifications for the indoor unit.

Outdoor Unit Dimensions

Physical dimensions and specifications for the outdoor unit.

Refrigerant Cycle Diagram

Wiring Diagrams

Indoor Unit Wiring Diagrams

Electrical schematics for indoor unit components (models 42LUVH025N-1, 42LUVH035N-1).

Indoor Unit Wiring Diagrams

Electrical schematics for indoor unit components (models 42LUVH045N-1, 42LUVH055N-1, 42LUVH065N-1).

Indoor Unit Wiring Diagrams

Electrical schematics for indoor unit components (model 42LUVH075N-1).

Outdoor Unit Wiring Diagrams

Electrical schematics for outdoor unit components (models 38LUVH025N-1, 38LUVH035N-1).

Outdoor Unit Wiring Diagrams

Electrical schematics for outdoor unit components (models 38LUVH055N-1, 38LUVH065N-1, 38LUVH075N-1).

Installation Details

Wrench Torque Specifications

Recommended torque values for installation fasteners to ensure secure connections.

Power Cord Connection Guidelines

Specifications for selecting appropriate power cords based on appliance current rating.

Pipe Length and Elevation Limits

Guidelines for refrigerant piping length, elevation differences, and additional refrigerant.

Air Purging Procedure with Vacuum Pump

Step-by-step instructions for evacuating the refrigerant system using a vacuum pump.

Gas Leak Detection Methods

Techniques for identifying refrigerant leaks using soap water or detergent.

Operation Description

Operational Abbreviations

Definitions of technical terms and symbols used in operation descriptions.

Main Protection Functions

Key safety mechanisms and protection features of the air conditioner unit.

Compressor Protection Details

Specific protections for compressor top temperature, discharge temperature, and inverter module.

Zero Crossing Error Protection

Mechanism to prevent failures due to incorrect AC time interval detection.

Fan Mode Operation

Description of the fan-only mode, including louver and fan speed settings.

Cooling Mode: Compressor Control

Rules governing compressor frequency based on temperature and time.

Cooling Mode: Fan Operation

Rules for outdoor and indoor fan operation in cooling mode, including auto fan.

Cooling Mode: Temperature Protections

Protections related to condenser and evaporator coil temperatures.

Heating Mode: Compressor Control

Rules governing compressor frequency during heating operations.

Heating Mode: Fan Operation

Rules for outdoor and indoor fan operation in heating mode.

Defrosting Mode Operation

Conditions and logic for initiating and managing the defrosting cycle.

Defrosting Mode End Conditions

Criteria for ending the defrosting cycle and resuming normal heating.

Evaporator Coil Temperature Protection

Protective measures against freezing or overheating of the evaporator coil.

Auto Mode Operation

Automatic selection of cooling, heating, or fan mode based on temperature difference.

Drying Mode Operation

Specific operating rules for drying mode, including temperature protection.

Forced Operation Function

How to manually activate forced auto or forced cooling modes.

Timer and Sleep Functions

Settings for timed operation and automatic adjustments during sleep mode.

Auto-Restart Functionality

How the unit resumes previous settings after a power interruption.

Optional Features: Ionizer and 8°C Heating

Details on the optional ionizer function and low-temperature heating mode.

Trouble Shooting

Indoor Unit Error Codes

List of error codes displayed on the indoor unit and their corresponding LED status.

EEPROM Parameter Error Troubleshooting

Diagnostic steps and solutions for EEPROM parameter errors.

Communication Error Troubleshooting

Diagnosing and resolving communication issues between indoor and outdoor units.

Fan Speed Control Issues

Troubleshooting steps for problems with indoor and outdoor fan speed control.

Temperature Sensor Faults

Diagnosing open or short circuits in temperature sensors.

IGBT Over-Current Protection

Troubleshooting IGBT over-strong current protection issues.

Voltage Protection Issues

Diagnosing and resolving over/under voltage protection errors.

Compressor High Temperature Protection

Troubleshooting steps for compressor high temperature protection.

Inverter Compressor Drive Errors

Diagnosing errors related to the inverter compressor drive system.

Zero Crossing Detection Error

Identifying issues when the main chip fails to detect over-zero signals.

Compressor Resistance Checks

Measuring winding resistance of various compressor models for diagnosis.

Outdoor Fan Motor Resistance Checks

Measuring winding resistance of different outdoor fan motor models.

Indoor Fan Motor Resistance Checks

Measuring winding resistance of indoor fan motor models RPG20D and RPG28D.

Step Motor Resistance Checks

Measuring winding resistance for step motor models MP2835, MP2423B, and MP2423.

Temperature Sensor R-T Data

Resistance-Temperature data tables for various temperature sensors.

Capacity Table

Capacity Table: 42;38 LUVH025 N-1

Cooling and heating capacity data for model 42/38LUVH025N-1 under various temperature conditions.

Capacity Table: 42;38 LUVH035 N-1

Cooling and heating capacity data for model 42/38LUVH035N-1 under various temperature conditions.

Capacity Table: 42;38 LUVH045 N-1

Cooling and heating capacity data for model 42/38LUVH045N-1 under various temperature conditions.

Capacity Table: 42;38 LUVH055 N-1

Cooling and heating capacity data for model 42/38LUVH055N-1 under various temperature conditions.

Capacity Table: 42;38 LUVH065 N-1

Cooling and heating capacity data for model 42/38LUVH065N-1 under various temperature conditions.

Capacity Table: 42;38 LUVH075 N-1

Cooling and heating capacity data for model 42/38LUVH075N-1 under various temperature conditions.