Energy Efficiency Ratio (EER) | 12.5 |
---|---|
Refrigerant | R-410A |
Operating Temperature (Cooling) | 5°F to 122°F |
Type | Ductless Mini Split |
Cooling Capacity | 24000 BTU/h |
Heating Capacity | 24000 BTU/h |
Power Supply | 208/230V, 1 Phase, 60 Hz |
Outdoor Unit Noise Level | 55 dB |
Defines hazard signal words used to alert users to potential injury or damage.
Lists electrical data including voltage, MCA, MOCP, RLA, and FLA for different unit sizes.
Illustrates the refrigerant flow through the indoor and outdoor units for heat pump operation.
Provides guidelines for sizing refrigerant lines, including minimum lengths and insulation requirements.
Lists maximum piping lengths, additional refrigerant charge, and pipe sizes for various unit configurations.
Details refrigerant charge adjustments for longer piping runs.
Outlines the procedure for evacuating the system using a vacuum pump.
Explains the deep vacuum method for system evacuation, emphasizing micron levels.
Describes the alternate triple evacuation method using nitrogen to remove moisture.
Details protection functions like compressor restart delay, temperature protection, and fan speed control.
Describes protection triggered by high condenser temperature, affecting compressor operation.
Explains protection that stops the compressor when evaporator temperature is too low.
Lists diagnostic codes (E0-E5, EC, F0-F5, P0-P4) for indoor units and their corresponding LED status.
Lists error codes, LED status (Green/Red), and corresponding IU display for Size 18 units.
Troubleshooting steps for EEPROM parameter errors, including PCB checks and replacement.
Troubleshooting for communication errors between indoor and outdoor units, covering wiring and PCB checks.
Troubleshooting steps for zero crossing detection errors, focusing on connections and PCB faults.
Troubleshooting for fan speed control issues, including wiring, motor, and PCB checks.
Details voltage measurements for DC fan motors to diagnose PCB or motor issues.
Guides on troubleshooting temperature sensor circuit errors, checking connections, resistance, and PCB.
Provides troubleshooting for refrigerant leakage detection, including sensor checks and system repairs.
Details troubleshooting for overload current protection, covering power supply, blockages, wiring, and compressor issues.
Offers troubleshooting for IPM or IGBT over-current protection, checking wiring, IPM, fan, and compressor.
Provides troubleshooting for over/under voltage protection, checking power, wiring, voltage, and reactor.
Guides on troubleshooting high temperature protection for the compressor, checking airflow, temperature, and OLP.
Details troubleshooting for inverter compressor drive errors, checking wiring, IPM, fan, and compressor.