EasyManua.ls Logo

Carrier 38MAQB24R-3 User Manual

Carrier 38MAQB24R-3
20 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
Specifications subject to change without notice.
Fig. 1 —Sizes 9K to 36K
NOTES: Read the entire instruction manual before starting the
installation.
Images are for illustration purposes only. Actual
models may differ slightly.
TABLE OF CONTENTS
PAGE
SAFETY CONSIDERATIONS........................................................2
INTRODUCTION ............................................................................3
ACCESSORIES................................................................................3
DIMENSIONS..................................................................................4
CLEARANCES ................................................................................7
INSTALLATION REQUIREMENTS .............................................8
INSTALLATION .............................................................................8
Step 1 - Check Equipment ................................................................8
Step 2 - Mount Unit ..........................................................................8
Step 3 - Condensate Drain Installation .............................................9
Step 4 - Refrigerant Piping ...............................................................10
Step 5 - Evacuate Coil And Tubing System .....................................13
Step 6 - Electrical Connections.........................................................14
WIRING ...........................................................................................14
ELECTRICAL DATA......................................................................15
CONNECTION DIAGRAMS ..........................................................15
START-UP .......................................................................................16
CARE AND MAINTENANCE........................................................16
TROUBLESHOOTING ...................................................................16
OUTDOOR UNIT DIAGNOSTIC GUIDES ...................................17
DUCTLESS START-UP CHECKLIST ...........................................18
Installation Instructions
38MA*R
Outdoor Unit Single Zone Ductless System
Sizes 09 to 36

Questions and Answers:

Carrier 38MAQB24R-3 Specifications

General IconGeneral
RefrigerantR-410A
Voltage208/230V
Phase1
Compressor TypeInverter
StagesVariable
Outdoor Unit Noise Level55 dB(A)
Cooling Capacity24000 BTU/h
Heating Seasonal Performance Factor (HSPF)10.0
Operating Temperature (Cooling)5°F - 122°F
Outdoor Unit Dimensions (H x W x D)35.4 x 12.6 inches

Summary

Safety Considerations

Hazard Warnings and Precautions

Specific safety warnings including electrical, explosion, and equipment damage hazards.

Installation Steps Part 1

Installation Steps Part 2

Installation Steps Part 3

Step 4: Refrigerant Piping

Instructions for running, cutting, and flaring refrigerant piping.

Installation Steps Part 4

Step 6: Connect the Pipes

Connecting refrigerant pipes to the indoor and outdoor units.

Step 7: Pressure Test Piping

Testing the refrigerant lines for leaks using nitrogen pressure.

Installation Steps Part 5

Step 5: Evacuate Coil and Tubing System

Procedure for removing air and moisture from the refrigerant circuit.

Installation Steps Part 6

Step 6: Electrical Connections

Wiring the outdoor unit power supply and communication lines.

Electrical Data and Diagrams

Troubleshooting

Unit Diagnostic Guides

Explanation of diagnostic codes and LED indicators for troubleshooting.

Outdoor Unit Diagnostic Guides

Ductless Start-Up Checklist

Ductless Start-Up Checklist (Continued)