High Temperature Protection of Compressor Top Diagnosis and Solution (P2)
Troubleshooting
Error Code P2
Malfunction decision conditions If the sampling voltage is not 5V, the LED displays the failure.
Supposed Causes
Power supply problems
System leakage or block
• PCB faulty
Power OFF.
Wait 10 minutes and re-start the unit.
No
Yes
Check the compressor temperature.
Is it within acceptable parameters?
Yes
Check the refrigerant system.
/ƐŝƚĨƵŶĐƟŽŶŝŶŐƉƌŽƉĞƌůLJ
Replace the outdoor control PCB.
Yes
Clear up the air inlet and outlet or the heat
exchanger of the indoor and outdoor units.
Yes
ŶƐƵƌĞĂƉƌŽƉĞƌĐŽŶŶĞĐƟŽŶ
No
Check the indoor and outdoor unit’s
ĂŝƌŇŽǁƐLJƐƚĞŵƐ
Does a problem exist?
Check the overload protector.
Is it properly wired?
No
Yes
Measure the resistance between the
two OLP ports.
Is it zero?
No
Replace the OLP.