18.2 Outdoor unit error code explanation: 
For other models, 
Display  LED STATUS 
E0  Outdoor EEPROM malfunction 
E2  Indoor / outdoor units communication error 
E3  Communication malfunction between IPM board and outdoor main board 
E4  Open or short circuit of outdoor unit temperature sensor(T3,T4.T5) 
E5  Voltage protection 
E6  PFC module protection 
E8 
Outdoor fan speed has been out of control or compressor speed has been out of control 
F1  No A Indoor unit coil outlet temperature sensor or connector of sensor is defective 
F2  No B Indoor unit coil outlet temperature sensor or connector of sensor is defective 
F3  No C Indoor unit coil outlet temperature sensor or connector of sensor is defective 
F4  No D Indoor unit coil outlet temperature sensor or connector of sensor is defective 
F5  No E Indoor unit coil outlet temperature sensor or connector of sensor is defective 
P0  Top temperature protection of compressor 
P1 
High pressure protection (For M4OB-36HFN8-Q, M5OD-42HFN8-Q) 
P2  Low pressure protection (For M4OB-36HFN8-Q, M5OD-42HFN8-Q) 
P3  Current protection of compressor 
P4  Temperature protection of compressor discharge 
P5  High temperature protection of condenser 
P6  IPM module protection 
E9  24k indoor unit wiring error 
LP  Low ambient temperature protection 
Note: Once these error codes display, they will  disappear in at least 30  seconds if the unit come back to 
normal.(Except E2&E3)