13
Heat pump heating performance (English)
See notes on pg. 14.
INDOOR
AIR
OUTDOOR COIL ENTERING AIR TEMPERATURES
°F
–3 7 172737475767
Capacity
Kw
Total
Power
Capacity
Kw
Total
Power
Capacity
Kw
Total
Power
Capacity
Kw
Total
Power
Capacity
Kw
Total
Power
Capacity
Kw
Total
Power
Capacity
Kw
Total
Power
Capacity
Kw
Total
Power
(F)
EDB CFM
Total Integ† Kw* Total Integ† Kw* Total Integ† Kw* Total Integ† Kw* Total Integ† Kw* Total Integ† Kw* Total Integ† Kw* Total Integ† Kw*
38YCB024-70 Outdoor Section With F(A,B)4ASF024 Indoor Section
65
700 9.25 8.51 1.32 11.6 10.7 1.49 14.1 12.9 1.68 16.7 14.9 1.87 19.7 18.0 2.09 23.0 23.0 2.34 26.8 26.8 2.64 31.0 31.0 2.99
800 9.45 8.69 1.34 11.8 10.9 1.51 14.4 13.1 1.70 17.0 15.1 1.89 20.1 18.3 2.10 23.5 23.5 2.35 27.3 27.3 2.64 31.6 31.6 2.99
900 9.62 8.85 1.37 12.0 11.0 1.54 14.6 13.3 1.72 17.3 15.4 1.91 20.4 18.5 2.12 23.8 23.8 2.36 27.7 27.7 2.65 32.1 32.1 2.99
70
700 8.87 8.16 1.33 11.2 10.3 1.51 13.8 12.5 1.70 16.4 14.5 1.91 19.3 17.6 2.13 22.6 22.6 2.39 26.3 26.3 2.69 30.4 30.4 3.05
800 9.07 8.35 1.35 11.5 10.5 1.53 14.0 12.8 1.72 16.7 14.8 1.92 19.6 17.9 2.14 23.0 23.0 2.40 26.8 26.8 2.70 31.0 31.0 3.05
900 9.25 8.51 1.38 11.6 10.7 1.56 14.2 13.0 1.75 16.9 15.0 1.94 19.9 18.1 2.16 23.3 23.3 2.41 27.2 27.2 2.70 31.5 31.5 3.05
75
700 8.45 7.77 1.34 10.9 9.99 1.52 13.4 12.2 1.73 16.0 14.2 1.94 18.9 17.2 2.17 22.1 22.1 2.44 25.8 25.8 2.75 29.8 29.8 3.11
800 8.66 7.96 1.36 11.1 10.2 1.55 13.6 12.4 1.75 16.3 14.4 1.96 19.2 17.5 2.19 22.5 22.5 2.44 26.3 26.3 2.75 30.4 30.4 3.10
900 8.84 8.14 1.39 11.3 10.4 1.57 13.8 12.6 1.77 16.5 14.6 1.98 19.5 17.7 2.20 22.8 22.8 2.46 26.6 26.6 2.76 30.8 30.8 3.11
Multipliers for Determining the Performance With Other Indoor Sections
Indoor
Section Size
Heating
Indoor
Section Size
Heating
Capacity Power Capacity Power
F(A,B)4ASF 024 1.00 1.00 FG3ASA 024 0.99 1.05
030 1.00 0.99 — — —
38YCB036-70, 90 Outdoor Section With F(A,B)4AS(F,B)036 Indoor Section
65
1050 14.7 13.6 2.15 18.5 17.0 2.35 22.3 20.4 2.57 26.3 23.4 2.79 31.0 28.2 3.03 36.2 36.2 3.31 42.0 42.0 3.64 48.4 48.4 4.03
1200 15.1 13.9 2.19 18.8 17.3 2.40 22.7 20.7 2.61 26.8 23.8 2.82 31.6 28.7 3.06 36.8 36.8 3.32 42.8 42.8 3.64 49.3 49.3 4.02
1350 15.4 14.2 2.24 19.1 17.6 2.44 23.1 21.1 2.65 27.2 24.2 2.85 32.0 29.1 3.08 37.3 37.3 3.34 43.4 43.4 3.66 50.0 50.0 4.03
70
1050 14.0 12.9 2.16 17.9 16.4 2.38 21.7 19.8 2.61 25.7 22.8 2.84 30.3 27.6 3.10 35.3 35.3 3.38 41.0 41.0 3.72 47.3 47.3 4.11
1200 14.4 13.2 2.21 18.2 16.7 2.43 22.1 20.2 2.65 26.2 23.2 2.87 30.8 28.1 3.12 36.0 36.0 3.40 41.8 41.8 3.72 48.3 48.3 4.11
1350 14.7 13.5 2.27 18.5 17.0 2.48 22.5 20.5 2.69 26.6 23.6 2.91 31.3 28.5 3.15 36.5 36.5 3.42 42.5 42.5 3.74 49.0 49.0 4.12
75
1050 13.3 12.2 2.18 17.2 15.8 2.41 21.1 19.3 2.65 25.1 22.3 2.89 29.6 26.9 3.16 34.5 34.5 3.45 40.1 40.1 3.79 46.3 46.3 4.19
1200 13.7 12.6 2.23 17.6 16.2 2.45 21.5 19.6 2.69 25.6 22.7 2.92 30.1 27.4 3.18 35.2 35.2 3.47 40.9 40.9 3.80 47.2 47.2 4.19
1350 14.0 12.8 2.28 17.9 16.5 2.50 21.9 20.0 2.73 25.9 23.0 2.96 30.6 27.8 3.21 35.7 35.7 3.49 41.5 41.5 3.81 47.9 47.9 4.20
Multipliers for Determining the Performance With Other Indoor Sections
Indoor
Section Size
Heating
Indoor
Section Size
Heating
Capacity Power Capacity Power
F(A,B)4ASF 036 1.00 1.00 FG3ASA 036 0.99 1.01
F(A,B)4AS(F,B) 042 1.00 0.97 — — —