EasyManuals Logo

Carrier 38YKC Series Installation And Start-Up Instructions

Carrier 38YKC Series
12 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #7 background imageLoading...
Page #7 background image
Fig. 10—Typical 24-v Circuit Connections using Carrier Model HP Thermostat with Smart Heat
and No Outdoor Thermostat, 1 Outdoor Thermostat, or 2 Outdoor Thermostats and
Carrier Model 2S Thermostat with FK4C/40FKA Fan Coil and Intelligent Staging
A97543
24 VAC HOT
R
G
W/W1
Y/Y2
O/W2
RVS COOLING
C
B
S1
S2
SUPPLEMENTAL
HEATING
RELAY
CARRIER
PROGRAMMABLE
THERMOSTAT
MODEL HP
FA, FB, FC, FH
FAN COIL WITH
SMART HEAT
HEAT 
PUMP
Y1/W2
L
R
C
Y
G
O
W2T
W3
W2D
Y
0
R
C
O
W2
Y
INDOOR FAN
HEAT STAGE 2
COOL/HEAT
STAGE 1
NOT USED
24 VAC COM
NOT USED
TROUBLE
OPTIONAL
OUTDOOR
SENSOR
CONNECTION
CUT
JW1
SHR
SHR
ODT
A97541
24 VAC HOT
R
G
W/W1
Y/Y2
O/W2
RVS COOLING
C
B
S1
S2
CARRIER
PROGRAMMABLE
THERMOSTAT
MODEL HP
FA, FB, FC, FH
FAN COIL WITH
SMART HEAT
HEAT 
PUMP
Y1/W2
L
R
C
Y
G
O
W2T
W3
W2D
Y
0
R
C
O
W2
Y
INDOOR FAN
HEAT STAGE 2
COOL/HEAT
STAGE 1
NOT USED
24 VAC COM
NOT USED
TROUBLE
OPTIONAL
OUTDOOR
SENSOR
CONNECTION
JW1
A98631
24 VAC HOT
R
G
W/W1
Y/Y2 Y/Y2
Y1/W2
R
DH
RVS COOLING
C
B
L
S1
S2
Y
W2
CARRIER
PROGRAMMABLE
THERMOSTAT
MODEL 2S
40FKA
FK4C
FAN COIL
HEAT
PUMP
G
O
O/W2
W2
Y1
C
W1
R
O
24 VAC COMM
HEAT STAGE 2
HEAT STAGE 3
COOL/HEAT
STAGE 1
FAN
RVS HEATING
TROUBLE
OUTDOOR
SENSOR
CONNECTION
C
J1 JUMPER
REMOVE
J2 JUMPER
FOR HEAT
STAGING
Intelligent Sequencing Application: Model 2S thermostat with
switch C OFF and switch D ON uses single-speed heat pump,
FK4 or 40FKA fan coil with selected 2:1 size ratio heaters. Provides 3
stages of auxiliary heat for even heating comfort via W/W1
and Y1/W2. Refer to FK4 or 40FKA Installation Instructions.
A97542
24 VAC HOT
R
G
W/W1
Y/Y2
O/W2
RVS COOLING
C
B
S1
S2
CARRIER
PROGRAMMABLE
THERMOSTAT
MODEL HP
ONE
OUTDOOR
THERMOSTAT
HEAT 
PUMP
Y1/W2
L
R
C
Y
G
O
W2T
W3
W2D
Y
0
R
C
O
W2
Y
INDOOR FAN
HEAT STAGE 2
COOL/HEAT
STAGE 1
NOT USED
24 VAC COM
NOT USED
TROUBLE
OPTIONAL
OUTDOOR
SENSOR
CONNECTION
CUT
JW1
ODT
FA, FB, FC, FH
FAN COIL WITH
SMART HEAT
7

Other manuals for Carrier 38YKC Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Carrier 38YKC Series and is the answer not in the manual?

Carrier 38YKC Series Specifications

General IconGeneral
BrandCarrier
Model38YKC Series
CategoryHeat Pump
LanguageEnglish

Related product manuals