Refrigerant | R-410A |
---|---|
Heating Seasonal Performance Factor (HSPF) | 9.0 |
Outdoor Unit Noise Level | 50 dB(A) |
Cooling Capacity | 12, 000 BTU/h |
Heating Capacity | 12000 BTU/h |
Operating Temperature (Heating) | 5°F - 86°F |
Outdoor Unit Dimensions (H x W x D) | 550 x 700 x 275 mm |
Warning about potential injury or death from electrical shock.
Warning about explosion risk from pressurized air/oxygen mixtures.
Caution about improper installation leading to equipment damage.
Guides on connecting power and communication wires between units.
Caution regarding proper wire sizing and secure connections.
Caution on avoiding wire contact with moving parts or tubing.
General rules for refrigerant line sizing and installation.
Specific instructions for systems with extended refrigerant line lengths.
Method for evacuating system to 500 microns for moisture removal.
Recommended method for thorough system evacuation and drying.
Important check for tubing integrity and securing after installation.
List of abbreviations for temperature sensors and other parameters.
Outlines the unit's primary protection mechanisms.
Protection that stops the unit if compressor overheats.
Protection based on compressor discharge temperature.
Error condition when fan speed is outside operational limits.
Protection functions for the inverter module.
Delay in indoor fan operation after unit starts.
Function to preheat the compressor in cold conditions.
Protection related to signal timing errors.
Protection for sensor failures.
System for detecting refrigerant leaks.
Describes different operating modes and fan control logic.
Protection triggered by high compressor temperature.
Protection triggered by low evaporator temperature.
Rules for compressor and fan operation in heating mode.
Procedure to manually initiate or exit defrost mode.
Conditions that cancel the defrost mode and return to heating.
Rules for forced cooling and auto modes.
Critical safety warning about capacitor discharge.
Identification and caution regarding electrolytic capacitors.
Diagnosis and solution for EEPROM parameter errors.
Diagnosis and solution for communication errors between units.
Procedure to test DC voltage for troubleshooting.
Procedure to test reactor resistance for troubleshooting.
Diagnosis and solution for zero-crossing detection errors.
Troubleshooting for indoor fan speed issues.
Troubleshooting for DC fan motor issues.
Troubleshooting for outdoor DC fan motor.
Troubleshooting for indoor AC fan motor.
Troubleshooting for temperature sensor faults.
Diagnosis and solution for refrigerant leakage detection.
Troubleshooting for overload current protection.
Troubleshooting for IPM or IGBT over-current protection.
Troubleshooting for over/under voltage protection.
Troubleshooting for compressor top high-temperature protection.
Troubleshooting for inverter compressor drive errors.
Guide for checking main components like sensors and windings.
Procedure to check temperature sensor resistance.
Procedure to check compressor winding resistance.
Procedure to check IPM continuity.
Procedure to measure fan motor winding resistance.
Table of resistance values for temperature sensors T1, T2, T3, T4.
Table of resistance values for temperature sensor T5.