5
Model YDK53-6K
Brand Welling
Input W 125
Capacitor uF 3.5
Outdoor fan motor
Speed r/min 800
a.Number of rows 2
b.Tube pitch(a)xrow pitch(b) mm 25.4x22
c.Fin spacing mm 1.4
d.Fin type (code) Hydrophilic aluminium
e.Tube outside dia.and type mm Ф9.53,innergroove tube
f.Coil length x height x width mm 797X660X44
Outdoor coil
g.Number of circuits 4
Outdoor fan Type and Diameter mm Propeller
Outdoor air flow m3/h 2500
Outdoor Sound pressure (LPA) @cooling dB(A) 59
Outdoor Sound power (LWA) @cooling dB(A)
Dimension(W*H*D) mm 845X695X335
Packing (W*H*D) mm 970X770X395
Outdoor unit
Net/Gross weight Kg 62/67
Refrigerant type R407c g 2000
Design pressure MPa 2.8
Liquid side/ Gas side mm(inch) Ф9.53/Ф16.0
Max. refrigerant pipe length m 20
Refrigerant piping
Max. difference in level m 10
pplication area m2 34~49
Remarks:
1.Cooling capacities are based on indoor air temp. 27℃ DB, 19℃ WB and outdoor air temp. 35℃ DB,
and 24℃ WB. Heating capacities are based on indoor air temp. 20℃ DB, 15℃ WB and outdoor air
temp. 7℃ DB, and 6℃ WB.
2. Indoor Sound Pressure level is measured in free field (JIS 9612 std) at 1m distance.
Outdoor Sound Pressure level is measured in hemispherical field, at 4m distance from the unit.
these values are normally somewhat different as a result of ambient condition.