d 42HQG018/024 & HWG455/605H-SERIES
After the power I/O button is pressed once, relays and AC SWITCH are turned on or off
per the remote control setpoint.
AC SWITCH U9 is controlled per the fan speed selection.
– Relay K1, K2, K3 are controlled per the operation mode selection.
If the power I/O button is pressed once more, relays and AC SWITCH are turned off and
the unit stops operation.
The unit turns on or off according to the temperature setpoint by sensing the room air
temperature through thermistor.
If the fan speed selection is set to the auto position, the fan speed is automatically
controlled according to the temperature difference between room temperature and
temperature setpoint.
40