Loading...
GB - 10
42PHW / 42PHQ / 42PHQ...K
Cooling only (42PHW 007, 009, 012, 014)
LNN
NY
Y
Cooling only (42PHW 018, 024)
RCY
RCYLN
 
 
230V ~ 50Hz
230V ~ 50Hz
IMPORTANT:
Make refrigerant connections before electrical
connections.
When disconnecting, disconnect electrical connections before
refrigerant connections.
For sizes 007 - 009 - 012 - 014 make ground connection prior
to any other electrical connections.
The mains supply must be connected as follows:
sizes 007 - 009 - 012 - 014: to the indoor unit;
sizes 018 - 024: to the outdoor init.
Make electrical connections between units prior to proceeding
to mains supply unit connection.
Before proceeding with the connection to the mains supply
locate live L and neutral N, then make connections as shown
in the wiring diagram.
Ensure that mains supply connection is made through a switch
that disconnects all poles, with contact gap of a least 3 mm.
The indoor - outdoor unit connecting wires must be A07 RN-F type
(or higher), with synthetic rubber insulation with Neoprene coating,
according to EN 60335-2-40 and HD277.S1 codes.
The mains supply connecting cable must be H07 RN-F type (or
higher), with synthetic rubber insulation with neoprene coating,
according to EN 60335-2-40 and HD277.S1 codes.
Ground connection between indoor and outdoor units is made
via the refrigerant pipes.
Notes:
All field electrical connections are the responsibility of the
installer.
Electrical connection
Indoor unit wiring
Lift the front panel up to the top of the unit; in this way the front
panel will be separated from the unit.
Remove the plastic cover of the terminal board.
Make the electrical connections to the terminal board as per the
wiring diagram.
When the electrical connections are completed, refit the terminal
board cover and fix the cables with the special cable holders.
Fix the front panel to the latch of the frame grille.