GB - 10
42PQV ...S
Indoor unit wiring
Lift the front panel up to the top of the unit; in this way the
front panel will be separated from the unit.
Remove the plastic cover of the terminal board.
Make the electrical connections to the terminal board as per
the wiring diagram.
When the electrical connections are completed, refit the
terminal board cover and fix the cables with the special cable
holders.
Fix the front panel to the latch of the frame grille.
IMPORTANT:
Make refrigerant connections before electrical connections.
When disconnecting, disconnect electrical connections before
refrigerant connections.
Make ground connection prior to any other electrical
connections.
Make electrical connections between units prior to proceeding to
mains supply unit connection.
Before proceeding with the connection to the mains supply
locate live L and neutral N, then make connections as shown in
the wiring diagram.
According to the installation instructions, the disconnecting
switches from the mains power supply should have a contact
gap (4mm) such that total disconnection can be ensured under
the conditions provided for by overvoltage class III.
The mains supply indoor unit - outdoor unit connecting cable
must be H07 RN-F (60245IEC66) type synthetic rubber
insulation with neoprene coating.
Ground connection between indoor and outdoor units is made
via the refrigerant pipes.
Notes:
All field electrical connections are the responsibility of the
installer.
Electrical connection
Heat pump (42PQV050S, 080S, 110S)
1
1
2
3
2
Note :
See outdoor units
installation manual.
Model GND 1 2 3
42PQV050S,080S,110S 4G1
Minimum connection wire size between
indoor and outdoor unit (mm
2
)
Terminal box legend
1 Live connection indoor/outdoor unit
2 Neutral connection indoor/outdoor unit
3 Communication (high voltage)
Interconnection cable (H07 RN-F)
Room Comtroller/CZM connecting cable
(Optional - see CRC installation manual)
10
35
10
45