EasyManuals Logo

Carrier 42QHC018DSW User Manual

Carrier 42QHC018DSW
48 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #17 background imageLoading...
Page #17 background image
14
6.3 Pipe length and the elevation
The pipe length and refrigerant amount:
Model
Pipe size
Standard
length
(m)
Max.
Elevation
B (m)
Max.
Length
A (m)
Additional
refrigerant
(g/m)
Gas Liquid
38KHC009DSP
38KHC012DSP
38QHC009ESWP
38QHC012ESWP
3/8’’(Ф9.52) 1/4’’(Ф6.35) 5 10 25 15
38KHC018DSP
38QHC018DSWP
1/2’’(Ф12.7) 1/4’’(Ф6.35) 5 20 30 15
38KHC024DSP
38QHC024DSWP
5/8’’(Ф15.9) 3/8’’(Ф9.52) 5 20 40 30
Caution:
The capacity test is based on the standard length and the maximum permissive length is based on the
system reliability.
The oil trap should be installed per 5-7 meters.

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Carrier 42QHC018DSW and is the answer not in the manual?

Carrier 42QHC018DSW Specifications

General IconGeneral
Model42QHC018DSW
Cooling Capacity18000 BTU/h
Energy Efficiency Ratio (EER)3.21
RefrigerantR-410A
Voltage220-240V
PhaseSingle
Compressor TypeRotary