Unit
Specifications
and Features
 Page 8-GB 
Operating temperature
When your air conditioner is used outside of the following temperature ranges, certain safety 
protection features may activate and cause the unit to disable.
Inverter Split Type 
COOL mode HEAT mode DRY mode
FOR OUTDOOR UNITS
WITH AUXILIARY
ELECTRIC HEATER
When outside 
temperature is below 
0°C (32°F), we strongly 
recommend keeping the 
unit plugged in at all time 
to ensure smooth ongoing 
performance.
Room Temperature
17°C - 32°C
(62°F - 90°F)
0°C - 30°C
(32°F - 86°F)
10°C - 32°C
(50°F - 90°F)
Outdoor 
Temperature
0°C - 50°C
(32°F - 122°F)
-15°C - 24°C
(5°F - 75°F)
0°C - 50°C
(32°F - 122°F)
-15°C - 50°C
(5°F - 122°F)
(For models with 
low temp. cooling 
systems.)
0°C - 52°C
(32°F - 126°F)
(For special 
tropical models)
0°C - 52°C
(32°F - 126°F)
(For special 
tropical models)
Fixed-speed Type
COOL mode HEAT mode DRY mode
Room
Temperature
17°C-32°C (62°F-90°F)
0°C-30°C
(32°F-86°F)
10°C-32°C (50°F-90°F)
Outdoor
Temperature
18°C-43°C (64°F-109°F)
-7°C-24°C
(19°F-75°F)
11°C-43°C (52°F-109°F)
-7°C-43°C (19°F- 109°F)
(For models with low-temp cooling systems)
18°C-43°C (64°F-109°F)
18°C-52°C (64°F -126°F)
(For special tropical models)
18°C-52°C (64°F- 126°F)
(For special tropical models)
NOTE: Room relative humidity less than 80%. If the air conditioner operates in excess of this 
gure, the surface of the air conditioner may attract condensation. Please sets the vertical air 
ow louver to its maximum angle (vertically to the oor), and set HIGH fan mode.
To further optimize the performance of your unit, do the following:
 ● Keep d
oors and windows closed.
 ● Limit energy usage by using TIMER ON and TIMER OFF functions.
 ● Do not block air inlets or outlets.
 ● Regularly inspect and clean air lters.