3
48LCD006A0A5A0A0A 0
123456789
10
11 12 13 14 15 16
17 18
Model Series - WeatherExpert
TM
LC - Ultra High Efficiency
Unit Heat Type
48 - Gas Heat Packaged Rooftop
Cooling Tons
04 - 3 ton
05 - 4 ton
06 - 5 ton
Heat Options
D = Low Gas Heat
E = Medium Gas Heat
F = High Gas Heat
L = Low Nox – Low Gas Heat
M = Low Nox – Medium Gas Heat
N = Low Nox – High Gas Heat
S = Low Heat w/ Stainless Steel Exchanger
R = Medium Heat w/ Stainless Steel Exchanger
T = High Heat w/ Stainless Steel Exchanger
(Low Nox models include – Stainless Steel HX)
Sensor Options
A = None
B = RA Smoke Detector
C = SA Smoke Detector
D = RA + SA Smoke Detector
E = CO
2
F = RA Smoke Detector and CO
2
G = SA Smoke Detector and CO
2
H = RA + SA Smoke Detector and CO
2
Indoor Fan Options
0 = Standard Electrical (Direct) Drive x13 ECM Motor
2 = Medium Static Belt Drive with VFD controller
3 = High Static Belt Drive with VFD controller
Refrig. Systems Options
0 = Two stage cooling capacity
A = Two stage cooling capacity
with Humidi-MiZer System
Coil Options: Fin/Tube (Condenser- Evaporator - Hail Guard)
A = Al/Cu - Al/Cu
B = Precoat Al/Cu - Al/Cu
C = E-coat Al/Cu - Al/Cu
D = E-coat Al/Cu - E-coat Al/Cu
E = Cu/Cu - Al/Cu
F = Cu/Cu - Cu/Cu
M = Al/Cu - Al/Cu — Louvered Hail Guard
N = Precoat Al/Cu - Al/Cu — Louvered Hail Guard
P = E-coat Al/Cu - Al/Cu — Louvered Hail Guard
Q = E-coat Al/Cu - E-coat Al/Cu — Louvered Hail Guard
R = Cu/Cu - Al/Cu — Louvered Hail Guard
S = Cu/Cu - Cu/Cu — Louvered Hail Guard
Voltage
1 = 575/3/60
5 = 208-230/3/60
6 = 460/3/60
Design Revision
A = Factory Design Revision
Base Unit Controls
0 = Base Electromechanical Controls
1 = RTU Open Multi-Protocol Controller
2 = ComfortLink Controls*
Intake / Exhaust Options
A = None
B =
Temperature Economizer with Barometric Relief
E = Enthalpy Economizer with Barometric Relief
N = Ultra Low Leak Temperature Economizer
with Barometric Relief
R = Ultra Low Leak Enthalpy Economizer with
Barometric Relief
Service Options
0 = None
1 = Unpowered Convenience Outlet
2 = Powered Convenience Outlet
3 = Hinged Panels
4 = Hinged Panels and
Unpowered Convenience Outlet
5 = Hinged Panels and
Powered Convenience Outlet
Packaging
0 = Standard
1 = LTL
Electrical Options
A = None
B = HACR Circuit Breaker
C = Non-Fused Disconnect
D = Thru-The-Base Connections
E = HACR Circuit Breaker
and Thru-The Base Connections
F = Non-Fused Disconnect and
Thru-The-Base Connections
Example:
Position:
* Not available for units equipped with Humidi-MiZer
C13382
Fig. 1 -- 48LC 04--06 Model Number Nomenclature (Example)